Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
8922A | 3 - Design Control Reference | 2 - Production Item | FLUKE CORPORATION | 89536 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 011263884 | A310A0 | 16449 | X | M | 3 | A | P | A | A | 0 | 10 Feb 1982 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YA | ||||||||||||||||||||||||||||||
YB | ||||||||||||||||||||||||||||||
ZA | ||||||||||||||||||||||||||||||
ZE | ||||||||||||||||||||||||||||||
ZH | ||||||||||||||||||||||||||||||
ZW | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
ZA01 | 1 Nov 1995 | |||||||||||||||||||||||||||||
ZE01 | 1 Oct 1996 | |||||||||||||||||||||||||||||
YB01 | 1 May 1997 | |||||||||||||||||||||||||||||
YA01 | 1 Oct 2000 | |||||||||||||||||||||||||||||
FGG4 | 3 | Z | F | D | FR | 1 Dec 2000 | ||||||||||||||||||||||||
NSGS | 3 | Z | 3 | D | JA | GG | 1 Dec 2000 | |||||||||||||||||||||||
ZH01 | 1 Nov 2009 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2009 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
An activity within the Air Force is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
End Item Primary Inventory Control Activity. This code identifies SICA managed end items or equipment assigned to another service PICA that is responsible for the wholesale logistics support functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance, if required, to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store, and issue functions for SICA activities. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA
Fleet Readiness Center South East (FRC-SE), Jacksonville FL
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | SB | 8922A | 89536 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | P | 738 | Z | 9 | A | H | Q | J | 061700 | X | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
77.5
Computing Equipment, Computer Components, and Circuit Cards
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Extremely fragile items including delicate instruments.
100.2
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Department of the Air Force
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTPT | Accuracy Rating | PORM PCT OF VOLTAGE READING ORPORM DB SINGLE INDICATOR ALL RANGES |
APPN | Accuracy In Percent | -0.5 TO 0.5 AT FULL SCALE SINGLE INDICATOR ALL RANGES |
CTTD | Circuit Attachment Method And Quantity | 1 RECEPTACLE, COAXIAL |
AACT | Circuit Current For Which Designed | AC |
BFQP | Display Digit Quantity | 3-1/2 |
BFQN | Display Type | LIGHT EMITTING DIODE |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
ANSY | Frequency Response Range | +0.000 TO 11.000 MEGAHERTZ |
BHMW | Measurement Range | +0.0 TO 700.0 VOLTS, AC SINGLE INDICATOR 1ST RANGE |
BHMW | Measurement Range | +0.0 TO 700.0 VOLTS, DC SINGLE INDICATOR 2ND RANGE |
BHMW | Measurement Range | +0.0 TO 100.0 PERCENT SINGLE INDICATOR 4TH RANGE |
BHMW | Measurement Range | +0.0 TO 131.0 DECIBELS SINGLE INDICATOR 3RD RANGE |
NHCF | Nuclear Hardness Critical Feature | NONHARDENED |
CTWN | Operating Voltage Rating In Volts | 100.0 AC MINIMUM AND 240.0 AC MAXIMUM |
AMQY | Installation Design | BENCH |
AMKD | Indicator Type | DIGITAL DISPLAY AND DIAL W/POINTER |
CTWZ | Interface Compatibility | IEEE-488 AND BCD AND RS-232-C |
AWZJ | Power Source | INTERNAL |
ABWG | Scale Division Quantity | 10 SINGLE INDICATOR SINGLE RANGE |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR SINGLE RANGE |
ABKW | Overall Height | 4.300 INCHES NOMINAL |
ABHP | Overall Length | 12.900 INCHES NOMINAL |
ABMK | Overall Width | 8.000 INCHES NOMINAL |
FAAZ | Phase | SINGLE |
FEAT | Special Features | AUTORANGING; AC OR AC PLUS DC MEASUREMENTS; TRUE-RMS AC WITH READOUT INVOLTS OR DB; SELECTABLE DBM REFERENCE IMPEDANCE; REAR PANEL LINEAR ANALOG OUTPUT; PEAKING/DIPPING METER |
STYL | Style Designator | RECTANGULAR OR SQUARE |