6625-01-162-6191

MULTIMETER


6625-01-162-6191 (6625011626191, 011626191)
Part Number (1 listing): 8860A-OPT05
Summary

FSG 66 / FSC 6625

DEMIL: Q

DEMIL INT: 6

HMIC: P

Date Created: 21 Sep 1983

MSDS: None

Hazmat: None

Export License Required:
Munitions List Item or Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-162-6191 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
8860A-OPT053 - Design Control Reference2 - Production ItemFLUKE CORPORATION  89536    CAGE 89536  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-162-6191 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625011626191A310A000794XM3QPAA021 Sep 1983
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

011626191

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-162-6191

A310A0

Federal Item Identification Guide (FIIG_4065)

00794

Item Naming Code (INC_4080)

21 Sep 1983

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-162-6191 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FGG4FEE400XD991 Sep 2000
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

X

Nonconsumable Item Material Support Code (NIMSC_0076)


All other conditions.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

99DSOR

Depot Source of Repair Codes (DSOR_0903)


Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-162-6191 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324SB8860A-OPT05  89536   CAGE/89536
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-162-6191 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597021 Sep 1983
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Sep 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-162-6191 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SED73839AHQJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Less Than Carload (LCL_CD_2760)


200

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-01-162-6191 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZXU1UEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

U

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-162-6191 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTPTAccuracy RatingPORM 0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 4TH RANGE
CTPTAccuracy RatingPORM 0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 5TH RANGE
CTPTAccuracy RatingPORM0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 2ND RANGE
CTPTAccuracy RatingPORM0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 3RD RANGE
CTPTAccuracy RatingPORM0.004 PCT OF READING PLUS 3 DIGITS SINGLE INDICATOR 1ST RANGE
AACTCircuit Current For Which DesignedAC
BFQPDisplay Digit Quantity5-1/2
BFQNDisplay TypeLIGHT EMITTING DIODE
AKYNFurnished Items And QuantityLINE CORD 1; TEST LEADS; INSTRUCTION/SERVICE MANUAL 1; IEEE-488 QUICK REFERENCE GUIDE 1; INSTRUMENT PERFORMANCE RECORD
ACZBFrequency Rating40.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM
BHMWMeasurement Range+0.0 TO 1000.0 VOLTS SINGLE INDICATOR 5TH RANGE
BHMWMeasurement Range+0.0 TO 2.0 VOLTS SINGLE INDICATOR 2ND RANGE
BHMWMeasurement Range+0.0 TO 20.0 VOLTS SINGLE INDICATOR 3RD RANGE
BHMWMeasurement Range+0.0 TO 200.0 VOLTS SINGLE INDICATOR 4TH RANGE
BHMWMeasurement Range+0.0 TO 200.0 MILLIVOLTS SINGLE INDICATOR 1ST RANGE
NHCFNuclear Hardness Critical FeatureNONHARDENED
CTWNOperating Voltage Rating In Volts100.0 AC MINIMUM AND 240.0 AC MAXIMUM
AMQYInstallation DesignBENCH
AMKDIndicator TypeDIGITAL DISPLAY
CTWZInterface CompatibilityIEEE-488
AWZJPower SourceEXTERNAL
BLSBScale Selection MethodSWITCH
ABFYOverall Depth14.600 INCHES NOMINAL
ABKWOverall Height3.500 INCHES NOMINAL
ABMKOverall Width8.500 INCHES NOMINAL
FEATSpecial FeaturesTEMPERATURE RANGE 0 DEG C TO 50 DEG C OPERATING,MINUS 40 DEG C TO PLUS 70 DEG C STORAGE; HUMIDITY RANGE 80 PCT RH 0 TO 35 DEG C,70 PCT TO 50 DEG C; WARMUP TIME 1 HOUR TO RATED SPECS
STYLStyle DesignatorPORTABLE W/TILT VIEW HANDLE


Back to Top
Back to Top