6625-01-234-5836

ANALYZER,DIGITAL DATA,ELECTRONIC TEST


6625-01-234-5836 (6625012345836, 012345836)
Part Numbers (3 listings): SBA200 | 10095000-101 | 19034500 |
Summary

FSG 66 / FSC 6625

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 17 Jun 1986

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-234-5836 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SBA2003 - Design Control Reference1 - Incomplete Part NumberL3 COMMUNICATIONS TELEMETRY-WEST  64854      
SBA2005 - Replaced / Discontinued9 - No Longer UsedL-3 COMMUNICATIONS CORPORATION  9U244      
10095000-1015 - Replaced / Discontinued9 - No Longer UsedHONEYWELL INTERNATIONAL INC.  94580    CAGE 94580  
190345005 - Replaced / Discontinued9 - No Longer UsedL3 COMMUNICATIONS TELEMETRY-WEST  64854      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-234-5836 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625012345836T263-C46820X1BPA017 Jun 1986
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

012345836

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-234-5836

T263-C

Federal Item Identification Guide (FIIG_4065)

46820

Item Naming Code (INC_4080)

17 Jun 1986

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-234-5836 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FGG4FEE400FEFR1 Sep 2000
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

FRDSOR

Depot Source of Repair Codes (DSOR_0903)


Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-234-5836 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597017 Jun 1986
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Jun 1986

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-234-5836 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SEP73839AHQJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

P

Less Than Carload (LCL_CD_2760)


77.5

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-01-234-5836 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZCU1TEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-234-5836 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AGAVEnd Item Identification10093064; U/O UG3600AY
ACYNAc Voltage Rating110.0 VOLTS MINIMUM AND 220.0 VOLTS MAXIMUM
ACZBFrequency Rating48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM
FTLDFunctional DescriptionCONDUCTS FULL PROTOCOL CHALLENGE TESTING FOR 1553 BUS INTERFACE; LOADS DATA OR PROGRAMS OVER BUS TO UUT
ABFYOverall Depth22.000 INCHES NOMINAL
ABKWOverall Height7.000 INCHES NOMINAL
ABMKOverall Width17.000 INCHES NOMINAL
FAAZPhaseSINGLE
FEATSpecial FeaturesINCLUDES MATE OPTION; CIIL INTERPRETER; IMBEDDED TMA; REMOTE CONTROL VIA RS-232 MODEM; FULL GPIB/IEEE 488 INTERRUPT CONTROL
AWJNUnpackaged Unit Weight30.000 POUNDS
SUPPSupplementary FeaturesOPER TEMP 40 TO 110 DEG F; OPER ALTITUDE 0 TO 10,000 FT


Back to Top
Back to Top