Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
3452-166 | 3 - Design Control Reference | 2 - Production Item | JEWELL INSTRUMENTS, LLC | 15309 | ![]() |
ST83D67-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOCKHEED MARTIN CORPORATION | 04236 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 012510114 | A310A0 | 61955 | X | 1 | A | P | A | 0 | 11 Mar 1987 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ||||||||||||||||||||||||||||||
FUGX | 3 | C | Z | SU | 1 Jul 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Ogden Air Logistics Center, Hill AFB, UT 84056-5609
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | E | TX | 3452-166 | 15309 | ![]() | ||||||
5 | 9 | A | TX | B | ST83D67-1 | 04236 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TH | 657 | Z | 9 | A | H | Z | W | 136740 | Z | 68820 | METERS-ELEC-PARTS |
Defense Supply Center Columbus, Columbus, OH 43215
Instruments, Electric Meter
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APPN | Accuracy In Percent | -1.0/+1.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES |
AQFY | Background Color | WHITE SINGLE INDICATOR ALL RANGES |
CTTD | Circuit Attachment Method And Quantity | 2 SOLDER LUG |
AACT | Circuit Current For Which Designed | DC |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR ALL RANGES |
AAPB | Dielectric Withstanding Voltage In Volts | 3000.0 |
AKYN | Furnished Items And Quantity | MTG HDW 3; TERM. HDW 2 |
ADZC | Environmental Protection | SHOCK RESISTANT AND VIBRATION RESISTANT |
CBBL | Features Provided | LUMINOUS SCALE MARKING AND MAGNETIC SHIELD AND ZERO ADJUSTER |
ZZZV | Fsc Application Data | TEST SET,ELECT. EQUIP. |
MATT | Material | STEEL |
APSW | Meter Body Diameter Behind Mounting Flange | 2.780 INCHES NOMINAL |
APST | Meter Depth Behind Mounting Flange | 1.650 INCHES MAXIMUM |
ANRL | Mounting Arrangement Style | THREE HOLE/STUD BOLT CIRCLE |
AFFL | Mounting Bolt Circle Diameter | 3.160 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 3 SCREW AND 3 UNTHREADED HOLE |
ABTB | Mounting Hole Diameter | 0.150 INCHES NOMINAL |
CTQL | Movement Suspension Method | JEWEL PIVOT BASE |
AQEC | Movement Type | MOVING COIL, PERMANENT MAGNET |
NHCF | Nuclear Hardness Critical Feature | NONHARDENED |
AMQY | Installation Design | PANEL |
AMKD | Indicator Type | DIAL W/POINTER |
ASSS | Pointer Color | BLACK SINGLE INDICATOR ALL RANGES |
ABWG | Scale Division Quantity | 50 SINGLE INDICATOR ALL RANGES |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR ALL RANGES |
ASTW | Scale Marking | X 1000 LBS; INNER RANGE: 0; 10; 20; 30; 40; 50;OUTER RANGE: 0; 50; 100; 150; 200; 250 |
ANTG | Sensitivity Rating | 1.0 MILLIAMPERES |
ADAV | Overall Diameter | 3.500 INCHES NOMINAL |
ABHP | Overall Length | 2.825 INCHES MAXIMUM |
FEAT | Special Features | RUGGEDIZED |
APSN | Panel For Which Designed | UNABLE TO DECODE OR UNABLE TO DECODE |
MARK | Special Markings | BOTH RANGES USE SAME GRADUATION MARKS |
SPCL | Special Test Features | CONFORMS TO MIL-M-10304/22 |
STYL | Style Designator | ROUND FLUSH MTG |
SUPP | Supplementary Features | 500 OHMS RESISTANCE |
SFTT | Surface Treatment | ENAMEL |