6625-01-291-1402

VOLTMETER


6625-01-291-1402 (6625012911402, 012911402)
Part Numbers (2 listings): 185011MTMT | 50-185-011MTMT |
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 24 Dec 1988

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-291-1402 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
185011MTMT3 - Design Control Reference2 - Production ItemYOKOGAWA CORPORATION OF AMERICA  60336      
50-185-011MTMT5 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  03516      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-291-1402 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625012911402A310A016449X1APU24 Dec 1988
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

012911402

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-291-1402

A310A0

Federal Item Identification Guide (FIIG_4065)

16449

Item Naming Code (INC_4080)

24 Dec 1988

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-291-1402 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-291-1402 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ETX185011MTMT  60336  
459ETXB50-185-011MTMT  03516  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-291-1402 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597024 Dec 1988
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Dec 1988

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-291-1402 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZA
Code Definitions

ZA

Originating Activity Code (ORIG_ACTY_CD_4210)


Australia

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-291-1402 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPNAccuracy In Percent-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
AQFYBackground ColorWHITE SINGLE INDICATOR SINGLE RANGE
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.844 INCHES NOMINAL
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.476 INCHES NOMINAL
CTTDCircuit Attachment Method And Quantity2 THREADED STUD
AACTCircuit Current For Which DesignedDC
APMMDial Scale Marking ColorBLACK SINGLE INDICATOR SINGLE RANGE
AAPBDielectric Withstanding Voltage In Volts1800.0
CBBLFeatures ProvidedMAGNETIC SHIELD AND ZERO ADJUSTER
MATTMaterialPLASTIC
BHMWMeasurement Range+0.0 TO 10.0 VOLTS, DC SINGLE INDICATOR SINGLE RANGE
ANRLMounting Arrangement StyleFOUR HOLE/STUD RECTANGULAR/SQUARE
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
CTQLMovement Suspension MethodJEWEL PIVOT BASE
AQECMovement TypeMOVING COIL, PERMANENT MAGNET
NHCFNuclear Hardness Critical FeatureNONHARDENED
ZZZVFsc Application DataELEC,ELECT. PROPERTIES MEASURING AND TEST INSTRUMENTS
AMQYInstallation DesignPANEL
AMKDIndicator TypeDIAL W/POINTER
ASSSPointer ColorBLACK SINGLE INDICATOR SINGLE RANGE
AWZJPower SourceEXTERNAL
ABWGScale Division Quantity40 SINGLE INDICATOR SINGLE RANGE
BHDCScale Graduation TypeLINEAR SINGLE INDICATOR SINGLE RANGE
ANTGSensitivity Rating1000.0 OHMS
ABKWOverall Height0.920 INCHES MAXIMUM
ABHPOverall Length3.440 INCHES NOMINAL
ABMKOverall Width2.258 INCHES NOMINAL
FEATSpecial FeaturesHORIZONTAL SCALE
STYLStyle DesignatorRECTANGULAR SURFACE MTG


Back to Top