6625-01-324-9157

COUNTER,ELECTRONIC,DIGITAL READOUT


6625-01-324-9157 (6625013249157, 013249157)
Part Numbers (2 listings): 575B-2-4-8-10B | 575B/OPT.2,4,8,10B |
Summary

FSG 66 / FSC 6625

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 24 Aug 1990

Unit Weight: 46.0 lbs

Unit Size: 31in x 28in x 15in

Unit Pack Cube: 7.534 cu ft

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-324-9157 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
575B-2-4-8-10B3 - Design Control Reference9 - No Longer UsedEIP MICROWAVE INC  34257      
575B/OPT.2,4,8,10B5 - Replaced / Discontinued9 - No Longer UsedEIP MICROWAVE INC  34257      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-324-9157 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625013249157T297-A26835X1BPAA024 Aug 1990
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

013249157

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-324-9157

T297-A

Federal Item Identification Guide (FIIG_4065)

26835

Item Naming Code (INC_4080)

24 Aug 1990

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-324-9157 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FGG4FEE43ZFEFR1 Sep 2000
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

FRDSOR

Depot Source of Repair Codes (DSOR_0903)


Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-324-9157 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597024 Aug 1990
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Aug 1990

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-324-9157 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SED73839AHQJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI1
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Less Than Carload (LCL_CD_2760)


200

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-01-324-9157 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZCU1TEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG W - PACKAGING DATA | NSN 6625-01-324-9157 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP41100046.0 lbs31in x 28in x 15in7.534 cu ft26.0 lbs16.8in x 14in x 3.5in
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XNV00B00M
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

46.0 lbs

Unit Pack Weight (UP_WT_5153)

31in x 28in x 15in

Unit Pack Size (UP_SZ_5154)

7.534 cu ft

Unit Pack Cube (UP_CU_5155)

26.0 lbs

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

16.8in x 14in x 3.5in

Unpackaged Item Dimensions (UNPKG_ITM_DIM_5158)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

NV

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-324-9157 Submit RFQ
MRCDecoded RequirementClear Text Reply
ASKXElectrical Connection Quantity2
AGBDElectrical Connection TypeBNC
AGAVEnd Item IdentificationCOUNTERMEASURES TEST SET,AN/ALM 233,P/N G134708-1
AZCGAccessory Component NamePOWER CORD AND OPERATING MANUAL
AFHSAccessory Component Quantity2
BFJCAccuracy RatingPORM COUNT,PORM TIME BASE ERROR
ACDCCurrent TypeAC
BFQPDisplay Digit Quantity12
BFQRDisplay Positioned Decimal PointPROVIDED
BFQNDisplay TypeLIGHT EMITTING DIODE
BFQSDisplay Storage FacilityINCLUDED
BFQQDisplay Units IndicatorINCLUDED
BFJFGate Time1.0 MICROSECONDS NOMINAL
BFJBFrequency Range+0.001/+20.000 GIGAHERTZ F1 INPUT RATIO
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
BFHZMeasurement TypeTIME INTERVAL
BFRDOutput Frequency WaveformSQUARE WAVE
BFQXInclosure Material And LocationALUMINUM BODY
ALSFInternal Battery AccommodationNOT INCLUDED
BFQMInternal Calibration FeatureNOT INCLUDED
BFQZPlug-In Units ProvisionNOT INCLUDED
BFQTRemote Control ProvisionsNOT INCLUDED
BFQWSolid State FeatureINCLUDED
ABKWOverall Height3.500 INCHES NOMINAL
ABHPOverall Length16.750 INCHES NOMINAL
ABMKOverall Width14.000 INCHES NOMINAL
FAAZPhaseSINGLE
FEATSpecial FeaturesSOURCE LOCKING WITH 10 KHZ RESOLUTION; USER SELECTABLE BANDWIDTH 10 KHZ 2 KHZ,500 HZ OR AUTOMATIC; FREQUENCY LIMITS FOR SELECTIVE FREQ/POWER MEASUREMENT; FREQ EXTENSION TO 110 GHZ
AWJNUnpackaged Unit Weight26.000 POUNDS
AMSEVoltage Rating100.0 VOLTS NOMINAL OR 230.0 VOLTS NOMINAL
ABJLWattage Rating In Watts200.0
BFRBStandard Frequency Output FeatureNOT INCLUDED


Back to Top