6625-01-359-2915

VOLTMETER


6625-01-359-2915 (6625013592915, 013592915)
Part Numbers (2 listings): 2250-F1 | 10106744-102 |
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 2 Jun 1992

Unit Weight: 9,999.9 lbs

Unit Size:

Unit Pack Cube: 1,149.000 cu ft

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-359-2915 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2250-F13 - Design Control Reference2 - Production ItemNORTH ATLANTIC INDUSTRIES, INC.  0VGU1    CAGE 0VGU1  
2250-F15 - Replaced / Discontinued9 - No Longer UsedNAI TECHNOLOGIES INC  07342    CAGE 07342  
10106744-1027 - Vendor Item Drawing Reference2 - Production ItemHONEYWELL INTERNATIONAL INC.  94580    CAGE 94580  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-359-2915 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625013592915A310A016449X43APA02 Jun 1992
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

013592915

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-359-2915

A310A0

Federal Item Identification Guide (FIIG_4065)

16449

Item Naming Code (INC_4080)

2 Jun 1992

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-359-2915 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Nov 2000
YA011 Jul 2001
ZU011 Apr 2006
ZH011 Apr 2008
MM861ZMEBA1 Mar 2015
YB011 Jul 2015
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

M

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Marine Corps is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

BADSOR

Depot Source of Repair Codes (DSOR_0903)


Maintenance Center Albany (MCA), Marine Corps Logistics Command (MCLC), Albany, GA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-359-2915 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59702 Jun 1992
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

2 Jun 1992

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-359-2915 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SEJ65839AHZJ136740A68820METERS-ELEC-PARTS-SUB1
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

J

Less Than Carload (LCL_CD_2760)


100.2

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

136740

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

A

NMFC Sub Item Number (SUB_ITM_NBR_0861)

68820

Uniform Freight Classification (UFC_CD_MODF_3040)

METERS-ELEC-PARTS-SUB1

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-01-359-2915 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DMMPBCY1DEA0
Code Definitions

MPB

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Commanding General, Marine Corps Logistics Command, 566–2, Bldg. 3700, Albany, GA 31704-5000

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

Y

Controlled Item Inventory Code (CIIC_2863)


Communication/electronic equipment and parts

1

Quantity Unit Pack (QUP_6106)


1

D

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps


FLIS - SEG W - PACKAGING DATA | NSN 6625-01-359-2915 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APZZZ9,999.9 lbs1,149.000 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00ZZZZZZZ0039A
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

Z

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Special Requirements - See specific instructions or drawings provided.

9,999.9 lbs

Unit Pack Weight (UP_WT_5153)

1,149.000 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

39

Special Marking Code (SP_MKG_CD_5169)


ESD sensitive electronic device requirements of MIL-STD-129 apply

A

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-359-2915 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length18.125 INCHES NOMINAL
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width2.250 INCHES NOMINAL
CTTDCircuit Attachment Method And Quantity2 CONNECTOR, PLUG
AACTCircuit Current For Which DesignedAC
CTQHDisplay ColorRED SINGLE INDICATOR SINGLE RANGE
BFQPDisplay Digit Quantity4-1/2
BFQNDisplay TypeLIGHT EMITTING DIODE
ACZBFrequency Rating10.0 HERTZ MINIMUM AND 100.0 KILOHERTZ MAXIMUM
BHMWMeasurement Range+0.02 TO 500.00 VOLTS SINGLE INDICATOR SINGLE RANGE
ANRLMounting Arrangement StyleFOUR SLOT RECTANGULAR/SQUARE OPEN ENDS
AXHRMounting Facility Type And Quantity4 SLOTTED HOLE
NHCFNuclear Hardness Critical FeatureNONHARDENED
CTWNOperating Voltage Rating In Volts115.0 AC MINIMUM AND 230.0 AC MAXIMUM
AMQYInstallation DesignBENCH OR RACK
AMKDIndicator TypeDIGITAL DISPLAY
AWZJPower SourceEXTERNAL
BLSBScale Selection MethodSWITCH
ABFYOverall Depth19.000 INCHES NOMINAL
ABKWOverall Height5.210 INCHES NOMINAL
ABMKOverall Width19.000 INCHES NOMINAL
FEATSpecial FeaturesSIGNAL AUTORANGING,UPRANGES AT APPROXIMATELY 109% OF RANGE.DOWNRANGESAT APPROXIMATELY 10% OF RANGE.
STYLStyle DesignatorRACK


Back to Top
Back to Top