6625-01-375-5581

ANALYZER,DIGITAL DATA,ELECTRONIC TEST


6625-01-375-5581 (6625013755581, 013755581)
Part Number (1 listing): R2600B/HS
Summary

FSG 66 / FSC 6625

DEMIL: C

DEMIL INT: 7

HMIC: P

Date Created: 14 May 1993

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-375-5581 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
R2600B/HS3 - Design Control Reference2 - Production ItemMOTOROLA SOLUTIONS, INC.  78205    CAGE 78205  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-375-5581 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625013755581T263-C46820XKCPA014 May 1993
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

013755581

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-375-5581

T263-C

Federal Item Identification Guide (FIIG_4065)

46820

Item Naming Code (INC_4080)

14 May 1993

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

C

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-375-5581 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FGG4FEE400XD991 Sep 2000
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

X

Nonconsumable Item Material Support Code (NIMSC_0076)


All other conditions.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

99DSOR

Depot Source of Repair Codes (DSOR_0903)


Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-375-5581 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597014 May 1993
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

14 May 1993

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-375-5581 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SEP73839AHCJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

P

Less Than Carload (LCL_CD_2760)


77.5

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

C

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Chemical corps items and all other chemicals not covered in other classifications. When chemical item (as indicated by the DOT Proper Shipping Name) is sensitive as defined in Appendix A Section I of DoD 4500.32ûR, Volume 1, second position must be from table 85, part 1.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-01-375-5581 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZL71UEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

U

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-375-5581 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
ACYNAc Voltage Rating115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM
ACYRDc Voltage Rating11.0 VOLTS MINIMUM AND 16.0 VOLTS MAXIMUM
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM
FTLDFunctional DescriptionPERFORMS SERVICE AND MAINTENANCE OF COMMUNICATIONS EQUIPMENT
AMKDIndicator TypeCATHODE RAY TUBE
ALSFInternal Battery AccommodationINCLUDED
ABKWOverall Height8.500 INCHES NOMINAL
ABHPOverall Length17.000 INCHES NOMINAL
ABMKOverall Width16.000 INCHES NOMINAL
FAAZPhaseSINGLE
FEATSpecial FeaturesOPTION IS TRACKER AND OCXO HIGH STABILITY TIMEBASE; SUPPLIED ACCESSORIES ARE: O-SCOPE PROBE RTL-4011A; BNC TON ADAPTER 58-84300A98; DC POWER CONNECTOR KIT RPX-4097A; ANTENNA TEKA-24A; MICROPHONE HMN-1056C; SIGNAL GENERATOR TERMINATION (50 OHM) 58-80386B73; OPERATOR MANUAL 68-80386B72; POWER CORD 30-80397A62; SPARE RF FUSES GG-6530277C002; INTERFACE PORTS: PRINTER/REMOTE CONTROL-RS-232 DB25 FEMALE; COLOR MONITOR-STD CGA RGB DB9 FEMALE
AWJNUnpackaged Unit Weight33.000 POUNDS
SUPPSupplementary FeaturesPERFORMS USUAL TESTING DONE BY:RFSIGNAL,SWEEP,AUDIO,AND DUPLEX OFFSET GENERATORS; SENSITIVE MEASUREMENT AND SCANNING RECEIVERS; SIGNAL STRENGTH,FREQUENCY ERROR,SINAD,DISTORTION METERS; SPECTRUM ANALYZER; FREQUENCY COUNTER; AC/DC VOLTMETER; RF WATTMETER; OSCILLOSCOPE; AND SIGNALLING SIMULATOR


Back to Top
Back to Top