6625-01-434-2239

MULTIMETER


6625-01-434-2239 (6625014342239, 014342239)
Part Numbers (2 listings): 76 | FLUKE76 |
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 24 Jul 1996

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-434-2239 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
763 - Design Control Reference2 - Production ItemFLUKE CORPORATION  89536    CAGE 89536  
FLUKE765 - Replaced / Discontinued2 - Production ItemFLUKE CORPORATION  89536    CAGE 89536  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-434-2239 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625014342239A310A000794XKAPA024 Jul 1996
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

014342239

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-434-2239

A310A0

Federal Item Identification Guide (FIIG_4065)

00794

Item Naming Code (INC_4080)

24 Jul 1996

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-434-2239 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZT011 Oct 1998
YA011 Dec 2001
ZR011 Dec 2007
ZA011 Nov 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-434-2239 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZZ76  89536   CAGE/89536
45269ZDFLUKE76  89536   CAGE/89536
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-434-2239 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597024 Jul 1996
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Jul 1996

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-434-2239 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-434-2239 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTPTAccuracy RatingPORM 1.5 PCT SINGLE INDICATOR ALL RANGES
CTTDCircuit Attachment Method And QuantityTEST PROD
AACTCircuit Current For Which DesignedAC AND DC
CTQHDisplay ColorBLACK SINGLE INDICATOR SINGLE RANGE
BFQPDisplay Digit Quantity4
BFQNDisplay TypeLIQUID CRYSTAL
AGAVEnd Item IdentificationCOMMON TEST EQUIPMENT
BHMWMeasurement Range+0.0 TO 0.1 MICROFARADS SINGLE INDICATOR 6TH RANGE
BHMWMeasurement Range+0.0 TO 1.0 KILOVOLTS, DC SINGLE INDICATOR 4TH RANGE
BHMWMeasurement Range+0.0 TO 10.0 AMPERES, DC SINGLE INDICATOR 2ND RANGE
BHMWMeasurement Range+0.0 TO 10.0 AMPERES, AC SINGLE INDICATOR 1ST RANGE
BHMWMeasurement Range+0.0 TO 20.0 KILOHERTZ SINGLE INDICATOR 3RD RANGE
BHMWMeasurement Range+0.0 TO 40.0 MEGOHMS SINGLE INDICATOR 5TH RANGE
BHMWMeasurement Range+0.0 TO 600.0 VOLTS, ROOT MEAN SQUARE SINGLE INDICATOR 7TH RANGE
CTWNOperating Voltage Rating In Volts9.0 DC NOMINAL
AMQYInstallation DesignHAND HELD
AMKDIndicator TypeDIGITAL DISPLAY
AWZJPower SourceINTERNAL
BLSBScale Selection MethodSWITCH
ABFYOverall Depth1.120 INCHES NOMINAL
ABHPOverall Length6.550 INCHES NOMINAL
ABMKOverall Width2.950 INCHES NOMINAL
STYLStyle DesignatorHAND-HELD


Back to Top