6625-01-441-2506

OSCILLOSCOPE


6625-01-441-2506 (6625014412506, 014412506)
Part Number (1 listing): 9350ALOPTCKTRIG,FD01,HD01
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 6 Feb 1997

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-441-2506 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
9350AL OPT CKTRIG,FD01,HD013 - Design Control Reference2 - Production ItemTELEDYNE LECROY, INC.  55716      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-441-2506 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625014412506T320-G00357X46APAA06 Feb 1997
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

014412506

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-441-2506

T320-G

Federal Item Identification Guide (FIIG_4065)

00357

Item Naming Code (INC_4080)

6 Feb 1997

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-441-2506 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZT011 Feb 1997
ZH011 May 2003
ZS011 Nov 2006
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-441-2506 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD9350AL OPT CKTRIG,FD01,HD01  55716  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-441-2506 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59706 Feb 1997
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Feb 1997

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-441-2506 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CL
Code Definitions

CL

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-441-2506 Submit RFQ
MRCDecoded RequirementClear Text Reply
BHDDAmplifier Deflection Sensitivity ProvisionNOT PROVIDED
BHDTAmplifier Input Impedance Rating ProvisionNOT PROVIDED
BHFFCalibrated Screen ScaleNOT INCLUDED
BHFTCamera Recording Device AccommodationNOT PROVIDED
ACDCCurrent TypeAC AND DC
ACZBFrequency Rating350.0 MEGAHERTZ MINIMUM AND 500.0 MEGAHERTZ MAXIMUM
BHDPFrequency Response RatingNOT PROVIDED
BHDHInput Intensity Modulation FeatureNOT PROVIDED
BHDLPlate Direct Connection Deflection Sensitivity ProvisionNOT PROVIDED
BGQKScreen Size12.5 BY 17.5 CENTIMETERS
ABFYOverall Depth8.500 INCHES NOMINAL
ABKWOverall Height16.250 INCHES NOMINAL
ABMKOverall Width14.500 INCHES NOMINAL
CXCYPart Name Assigned By Controlling Agency9350A FAMILY DIGITAL OSCILLOSCOPE 500 MHZ BANDWIDTH 2GS/S
FEATSpecial FeaturesOPTION CKTRIG HAS 500 MEGAHERTZ EXTERNAL CLOCK 10 MEGAHERTZ REFERENCE INPUT TRIGGER COMPARATOR OUTPUT 64 MEGABYTE PROCESSING MEMORY; OPTION FD01 IS INTERNAL 3.5 INCH FLOPPY DRIVE WITH CENTRONICS INTERFACE; OPTION HD01 IS HARD DISK ADAPTOR; OPERATING TEMPERATURE 41 DEGF TO 104 DEGF
BHFRTrace Erasing ProvisionNOT PROVIDED
BHFHTrace Storage TubeNOT INCLUDED
BHDJVisual Modulation Sensitivity Voltage Rating2.0 MILLIVOLTS MINIMUM AND 5.0 MILLIVOLTS MAXIMUM
AMSEVoltage Rating120.0 MILLIVOLTS NOMINAL
BGQLSweep CircuitsNOT INCLUDED


Back to Top
Back to Top