Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
4421A300 | 3 - Design Control Reference | 2 - Production Item | BIRD ELECTRONIC CORPORATION | 70998 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 014461290 | T228-F | 21191 | X | K | A | P | A | 0 | 23 Jun 1997 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FGG4 | FEE4 | 3 | Z | F | D | FR | 1 Sep 2000 | |||||||||||||||||||||||
MF5S | 3 | Z | 2 | D | BA | 1 Sep 2011 | ||||||||||||||||||||||||
ZU01 | 1 Sep 2011 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
An activity within the Air Force is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Exception Item (Depot Reparable Component or SICA Managed Consumable). This code identifies SICA managed depot reparable components, or SICA managed consumables wherein the SICA cannot use repaired items, assigned to another service which has responsibility for the logistics functions of single submitter of cataloging data, acquisition and disposal authority. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by PICA. The SICA service has retained the wholesale stock, store, and issue functions in support of SICA activities and has retained depot repair capability, where applicable. Retention of depot maintenance capability for the depot reparable components requires documented justification by the SICA to the PICA via JLC Form 9. If the PICA and SICA cannot reach an agreement, the documentation will be forwarded to the joint MISMOs for a decision. The SICA CMD will reflect Source of Supply or SoS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA
Maintenance Center Albany (MCA), Marine Corps Logistics Command (MCLC), Albany, GA
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | ZZ | 4421A300 | 70998 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 23 Jun 1997 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TK | M | 738 | 3 | 9 | A | H | Z | J | 061700 | X | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000
85
Computing Equipment, Computer Components, and Circuit Cards
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Commanding General, Marine Corps Logistics Command, 566–2, Bldg. 3700, Albany, GA 31704-5000
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
Department of the Air Force
U.S. Marine Corps
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ACYN | Ac Voltage Rating | 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL |
AFJH | Furnished Items | C/O 4421 WATTMETER, 4421A503 IEEE488 MICROCIRCUIT PROGRAMMER, METER CASE, 4021 DIRECTIONAL COUPLER, 4022 DIRECTIONAL COUPLER, MALE NRF DIRECTIONAL COUPLER, SENSOR CABLE, CALIBRATION KEY(ADAPTER), PROGRAM DISKS, SERVICE MANUAL; AN IBM PC/AT OR COMPATIBLE COMPUTER IS NOT INCLUDED WITH TEST SET BUT ISREQUIRED, REFER TO INSTRUCTION BOOK |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
HGTH | Height | 4.000 INCHES NOMINAL |
ANSX | Measurement Unit | AVERAGE POWER AND PEAK POWER |
AREN | Input Frequency Range | +50.000 TO 60.000 HERTZ |
ANPZ | Inclosure Feature | MULTIPLE ITEM W/CARRYING CASE |
ABRY | Length | 16.000 INCHES NOMINAL |
AREP | Radio Frequency Input Power Rating | 0.3 WATTS MINIMUM AND 1200.0 WATTS MAXIMUM |
ABWC | Scale Unit Of Measure Inscription | KILOWATTS AND WATTS |
FEAT | Special Features | FOUR SCALE RANGES .180 KW TO 1.99WATTS SELECTED BY USING EITHER AUTO OR MANUAL RANGING EITHER BY LOCAL OR REMOTE CONTROL; LCD DISPLAY, 3 1/2 DIGITS WITH BACKLIGHT; ACCURACY PORM 1 DIGIT; RETURN LOSS 0 TO 40 DB; VSWR RANGE 1.0 TO 199.9; WEIGHS 11.0 LBS; COMES WITH 7.5 FT POWER CORD |
ABGL | Width | 12.000 INCHES NOMINAL |