Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MODEL 7500DT | 3 - Design Control Reference | 2 - Production Item | ASSOCIATED RESEARCH INCORPORATED | 04237 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6625 | 015197519 | T228-A | 03637 | X | 4 | 6 | A | P | A | A | 0 | 29 Apr 2004 |
Electrical and Electronic Properties Measuring and Testing Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZG01 | 1 Apr 2004 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | MODEL 7500DT | 04237 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 29 Apr 2004 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKWC | Electrical Power Source Relationship | OPERATING |
ACYN | Ac Voltage Rating | 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
ACZB | Frequency Rating | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM |
FTLD | Functional Description | PERFORMS 500 VA AC HIPOT TESTING ALONG WITH 6 KV DC HIPOT AND INSULATION RESISTANCE TESTING THROUGH A SINGLE DUT CONNECTION; BEST SUITED FOR AUTOMATED APPLICATIONS THAT REQUIRE 500 VA TESTING; CAN BE USED AS A BENCH TOP TESTER OR AS A PC CONTROLLED SYSTEM USED IN TANDEM WITH ASSOCIATED RESEARCH AUTOWARE CONTROL SOFTWARE |
HGTH | Height | 5.800 INCHES NOMINAL |
AQXZ | Operating Test Capability | 500 VA AC HIPOT TESTING ALONG WITH 6 KV DC HIPOT AND INSULATION RESISTANCE TESTING THROUGH A SINGLE DUT CONNECTION |
ANPZ | Inclosure Feature | SINGLE ITEM W/HOUSING |
ABRY | Length | 17.000 INCHES NOMINAL |
CXCY | Part Name Assigned By Controlling Agency | FULLY-AUTOMATED DIELECTRIC ANALYZER; MULTI-FUNCTION ELECTRICAL SAFETY COMPLIANCE ANALYZER |
FAAZ | Phase | SINGLE |
FEAT | Special Features | VOLTAGE IS USER SELECTABLE; 6.3 AMP 250 V SLO-BLO FUSE |
ABGL | Width | 16.500 INCHES NOMINAL |
AQXY | Test Type For Which Designed | ELECTRICAL SAFETY COMPLIANCE |