6625-01-552-9839

CONTROLLER,TEST,ELECTRONIC SYSTEM


6625-01-552-9839 (6625015529839, 015529839)
Part Number (1 listing): MODEL407
Summary

FSG 66 / FSC 6625

DEMIL: Q

DEMIL INT: 6

HMIC: P

Date Created: 29 Jun 2007

MSDS: None

Hazmat: None

Export License Required:
Munitions List Item or Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-552-9839 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MODEL 4073 - Design Control Reference2 - Production ItemMTS SYSTEMS CORPORATION  34145      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-552-9839 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625015529839A3170045808X1QPAA029 Jun 2007
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

015529839

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-552-9839

A31700

Federal Item Identification Guide (FIIG_4065)

45808

Item Naming Code (INC_4080)

29 Jun 2007

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-552-9839 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC
ZC011 Jun 2007
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-552-9839 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDMODEL 407  34145  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-552-9839 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
DF
Code Definitions

DF

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Tank Automotive Command, Warren, MI 48090

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-552-9839 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADTVCase MaterialMETAL
AMPSCurrent Rating In Amps5.0
CHQRMaximum Overall Height5.200 INCHES
CHQPMaximum Overall Length16.500 INCHES
CHQQMaximum Overall Width8.800 INCHES
AFXEMaximum Voltage Rating In Volts250.0 AC
AZQHMaximum Wattage Rating In Watts125.0
AXGYMounting MethodPORTABLE
AFGAOperating Temp Range+10.0/+40.0 DEG CELSIUS
AKNAInclosure TypeENCASED
ATJKPower SourceEXTERNAL
CXCYPart Name Assigned By Controlling AgencySERVOCONTROLLER
APXHTerminal LocationBACK
CCFFTerminal Type And Quantity1 JACK


Back to Top
Back to Top