6625-01-587-7128

TEST SET,POWER SUPPLY


6625-01-587-7128 (6625015877128, 015877128)
Part Number (1 listing): 200518282
Summary

FSG 66 / FSC 6625

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 17 Aug 2010

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-587-7128 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2005182823 - Design Control Reference2 - Production ItemWARNER ROBINS AIR LOGISTICS CENTER  98752    CAGE 98752  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-587-7128 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625015877128T228-A03658XKBPA017 Aug 2010
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

015877128

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-587-7128

T228-A

Federal Item Identification Guide (FIIG_4065)

03658

Item Naming Code (INC_4080)

17 Aug 2010

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-587-7128 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FGG400FDFR1 Aug 2010
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

FRDSOR

Depot Source of Repair Codes (DSOR_0903)


Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA


FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-587-7128 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32CZZ200518282  98752   CAGE/98752
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

C

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing. The drawing is available for unlimited use but under the security measures specified for the level of security classification assigned. The drawing will be furnished only to qualified requesters by the activity identified by the RNAAC.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6625-01-587-7128 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597017 Aug 2010
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Aug 2010

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-587-7128 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TKP73839AHQJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

P

Less Than Carload (LCL_CD_2760)


77.5

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6625-01-587-7128 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZYU1SEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

S

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-587-7128 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AGAVEnd Item IdentificationAIM-9M LAUNCHER POWER SUPPLY
ACYNAc Voltage Rating115.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT
AEJZDepth55.000 INCHES MAXIMUM
ACZBFrequency Rating60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT
FTLDFunctional DescriptionDUAL CONSOLE AND WORK BENCH USED TO PERFORM FINAL ACCEPTANCE TESTING OF AIM-9M LAUNCHER POWER SUPPLIES
HGTHHeight64.000 INCHES NOMINAL
ANPZInclosure FeatureMULTIPLE ITEM W/HOUSING
AEASMajor ComponentsBAY 1: POWER SWITCH, SPEAKERS, MONITOR, DC POWER SUPPLY, 2 DRAWERS, KEYBOARD/MOUSE DRAWER, WORK SURFACE, 115VAC 400HZ POWER SUPPLY, AF POWER SUPPLYDC LOAD; BAY 2: POWER SWITCH, TEMPORARY POWER SUPPLY (UPS), OSCILLOSCOPE, COMPUTER, 2 DATA SWITCHES, TEST RECEPTACLE, WORK SURFACE, PRINTER, DRAWER, DC LOAD, INTERFACE PCB
RDALReference Data And LiteratureTO 33D9-53-100-3
CXCYPart Name Assigned By Controlling AgencySIDEWINDER LAUNCHER POWER SUPPLY TEST STATION
FAAZPhaseSINGLE 1ST ALTERNATE OPERATING POWER RQMT
ABGLWidth48.000 INCHES NOMINAL
AQXYTest Type For Which DesignedPOWER


Back to Top