6625-01-645-0677

WAVEMETER


6625-01-645-0677 (6625016450677, 016450677)
Part Number (1 listing): G1315C
Summary

FSG 66 / FSC 6625

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 2 Jun 2015

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6625-01-645-0677 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
G1315C3 - Design Control Reference2 - Production ItemAGILENT TECHNOLOGIES, INC.  1MY97    CAGE 1MY97  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6625-01-645-0677 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666625016450677T134-H00783X43APAA02 Jun 2015
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6625

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical and Electronic Properties Measuring and Testing Instruments

016450677

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6625-01-645-0677

T134-H

Federal Item Identification Guide (FIIG_4065)

00783

Item Naming Code (INC_4080)

2 Jun 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6625-01-645-0677 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Jun 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6625-01-645-0677 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43219ZDG1315C  1MY97   CAGE/1MY97
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6625-01-645-0677 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
DF
Code Definitions

DF

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Tank Automotive Command, Warren, MI 48090

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6625-01-645-0677 Submit RFQ
MRCDecoded RequirementClear Text Reply
BDHWCalibration Accuracy Rating+/- 1 NM, SELF-CALIBRATION WITH DEUTERIUM LINES, VERIFICATION WITH HOLMIUM OXIDE FILTER
APTTOperating Frequency80.0 HERTZ NOMINAL
BDHSInstrument Calibration Range190-950NM
CXCYPart Name Assigned By Controlling AgencyDIODE-ARRAY DETECTOR SL
AMKDIndicator TypeMICROMETER
FEATSpecial FeaturesDATA ANALYSIS SOFTWARE FOR SPECTRA EVALUATION, INCLUDING SPECTRAL LIBRARIES AND PEAK PURITY FUNCTIONS; DETECTOR TYPE: 1024-ELEMENT DIODE ARRAY; FLOW CELLS: STANDARD: 13MICROLITER VOLUME, 10 MM CELL PATH LENGTH 120 BAR (1760 PSI) PRESSURE MAXIMUM; SEMI-MICRO: 5MICROLITER VOLUME, 6 MM CELL PATH LENGTH, 120 BAR (1760 PSI) PRESSURE MAXIMUM; MICRO: 2MICROLITER VOLUME, 3 MM CELL PATH LENGTH, 400 BAR (5880 PSI) PRESSURE MAXIMUM; NANO: 80 NANOLITER VOLUME, 6 MM CELL PATH LENGTH, 50 BAR (735 PSI) PRESSURE MAXIMUM
AMSEVoltage Rating1.0 VOLTS NOMINAL


Back to Top