Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
74070 | 3 - Design Control Reference | 2 - Production Item | PRECISION SCIENTIFIC PETROLEUM | 48619 | ![]() |
74070 | 3 - Design Control Reference | 2 - Production Item | PRECISION SCIENTIFIC PETROLEUM | 48619 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6630 | 013571399 | T396-C | 19133 | X | 1 | A | N | A | 0 | 17 Apr 1992 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 6 | 17 Apr 1992 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AEHZ | Maximum Operating Temp | 100.0 DEG FAHRENHEIT |
FEAT | Special Features | 120.0 VAC,50.0/60.0 HZ,1430 WATTS; TEST CAPACITY: ONE TO FOUR IMMERSION TYPE RVP BOMBS WITH QUICK DISCONNECT; TEST CYCLE: 4 MINS; SHAKING RATE: 50 OR 170 OSCILLATIONS PER MIN.; BATH VOLUME: 8.4 GALLONS DISTILLED WATER; TEMPERATURE CONTROL: RTD SENSOR,PID CONTROLLER W/LED TEMP. DISPLAY; EVAPORATION CONTROL: 2 STAINLESS STEEL HINGED COVERS; OVERALL DIMENTIONS: 37.0 IN. W.,20.0 IN. D.,18.0 IN. H.; BATH INTERIOR: 27.250 IN. W.,9.625 IN. D.,6.000 IN. CLEARANCE ABOVE OSCILLATION; SHIPPING WT: 110.0 LBS. DOMESTIC AND AIR PACK; SHIPPING VOLUME: 14.0 CUBIC FEETUNIFORMITY CONTROL: FORCED AIR CIRCULATION |