Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
98-20748-00/WKIT1001 | 3 - Design Control Reference | 2 - Production Item | IDEXX LABORATORIES, INC. | 0USV5 | ![]() |
QUANTI-CULT | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | IDEXX LABORATORIES, INC. | 0USV5 | ![]() |
F93G330 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | AIR FORCE MEDICAL LOGISTICS OFFICE | 66735 | ![]() |
WKIT-1001 | 5 - Replaced / Discontinued | 9 - No Longer Used | IDEXX LABORATORIES, INC. | 0USV5 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6630 | 013780445 | A23800 | 14890 | X | 4 | 9 | A | Y | A | 0 | 10 Aug 1993 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE01 | 1 Nov 1997 | |||||||||||||||||||||||||||||
ZC01 | 1 Feb 2007 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | ZZ | 98-20748-00/WKIT1001 | 0USV5 | ![]() | ||||||
5 | 1 | 4 | ZZ | QUANTI-CULT | 0USV5 | ![]() | ||||||
5 | 1 | 4 | ZZ | F93G330 | 66735 | ![]() | ||||||
5 | 9 | 4 | ZZ | B | WKIT-1001 | 0USV5 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 10 Aug 1993 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KX |
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
No Variation. NMFC and UFCC Match.
DLA Troop Support, Director of Medical Material, Philadelphia, PA 19145 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Set - A collection of matched or related items issued as a single item of supply, i.e., tool sets, instrument sets, and matched sets. Use only when the term “set” is a part of the item name.
TYPE I (06 Months ) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AJJW | Component Quantity | 9 |
AJKD | Nonsupply Items And Quantities | VIAL ORGANISM ESCHERICHIA COLI 3; VIAL ORGANISM KLEBSIELLA PNEUMONIAE 3; VIAL ORGANISM PSEUDOMONAS AERUGINOSA 3 |
FEAT | Special Features | DEHYDRATED LIVE GEL CULTURES; PRE-QUANTITATED LOW LEVELS OF BACTERIA AS RECOMMENDED BY EPA FOR VALIDATING COLILERT SYSTEM OR OTHER COLIFORM AND E. COLI METHODS; W/REHYDRATING FLUID (ONE VIAL EACH ORGANISM) |