Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
G3442B | 3 - Design Control Reference | 2 - Production Item | AGILENT TECHNOLOGIES, INC. | 1MY97 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6630 | 016543193 | A23900 | 61620 | X | 4 | 2 | A | N | A | A | 0 | 25 Apr 2016 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
The approved item name applied to this item exists for use exclusively with the partial descriptive method of item identification - Miscellaneous Items Federal Item Identification Guide A239.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Apr 2016 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | G3442B | 1MY97 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW |
Turkey
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CXCY | Part Name Assigned By Controlling Agency | CHROMATOGRAPH, GAS |
ABKW | Overall Height | 19.2 INCHES NOMINAL |
ABHP | Overall Length | 20.2 INCHES NOMINAL |
ABMK | Overall Width | 22.9 INCHES NOMINAL |
FEAT | Special Features | FOUR INTERNAL 24-VOLT CONNECTIONS (UP TO 150MA), TWO EXTERNAL 24-VOLT CONNECTIONS (UP TO 150MA); TWO ON/OFF CONTACT CLOSURES (48 V.250 MA MAX); 550 TIMED EVENTS VIA DATA SYSTEM; 50 TIMED EVENTS VIA GC KEYBOARD; SUPPORT FOR UP TO 8 VALVES, VALVES 1 TO 4, 12V DC 13 WATT IN A HEATED VALVE BOX, VALVES 5 TO 6, 24 V DC 100 MA UNHEATED, FOR LOW POWER VALVE APPLICATIONS, VALVES 7 TO 8 ARE EXTERNALLY POWERED AS A REMOTE EVENT FROM A SEPARATE CONTACT CLOSURE; INDEPENDENT HEATED ZONES, MAXIMUM OPERATING TEMPERATURES FOR AUXILIARY ZONES 400 DEGREES CELCIUS; CONFORMS TO INTERNATIONAL, CANADIAN, AND US STANDARDS |
CSBH | Voltage In Volts And Current Type | 120.0 AC AND 240.0 AC-PEAK |