6635-00-191-7870

TESTER,MATERIAL HARDNESS


6635-00-191-7870 (6635001917870, 001917870)
Part Number (1 listing): 3JS
Summary

FSG 66 / FSC 6635

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 4 Mar 1970

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6635-00-191-7870 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
3JS3 - Design Control Reference9 - No Longer UsedPAGE-WILSON CORP  82729      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6635-00-191-7870 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666635001917870T264-B18992XKANU4 Mar 1970
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6635

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Physical Properties Testing and Inspection

001917870

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6635-00-191-7870

T264-B

Federal Item Identification Guide (FIIG_4065)

18992

Item Naming Code (INC_4080)

4 Mar 1970

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6635-00-191-7870 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6635-00-191-7870 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3393CXD3JS  82729  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6635-00-191-7870 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX011 Nov 1978
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Nov 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6635-00-191-7870 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CXF653Z9ASZF058240X33170RECORDING-DEVICES-GAUGES-METERS-NOI
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

F

Less Than Carload (LCL_CD_2760)


150

653

Water Commodity Code (WRT_CMDTY_CD_9275)


Musical Instruments

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

S

Air Commodity Code (AIR_CMTY_HDLG_9215)


Office, School, and Household Supplies/Equipment including Office Machines, Furniture/Stationary, Films, Synthetic/Special Training Films, Non-Hazardous Household Cleaning Products, Non-Hazardous Personal Hygiene Products, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

058240

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

33170

Uniform Freight Classification (UFC_CD_MODF_3040)

RECORDING-DEVICES-GAUGES-METERS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6635-00-191-7870 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKYDAccessory Components And QuantityANVIL,CYLINDRICAL WORK 1; ANVIL,PLANE SURFACE 1; ANVIL,RAISED SPOT 1; ANVIL,SHALLOW V 1; CHUCK,1/16 IN. STEEL BALL PENETRATOR,W/50 STEEL BALLS 1; COVER,PLASTIC 1; WEIGHTS,FOR APPLYING 15 KG,30 KG,AND 45 KG MAJOR LOADS ) SET; SLEEVE SET,PROTECTIVE,FOR ELEVATING SCREW 1; TEST BLOCKS FOR N SCALE 2; TEST BLOCKS FOR T SCALE 1; TEST POINT AND DIAL ILLUMINATOR 1
AFJUCarrying CaseNOT PROVIDED
BCKTHorizontal Reach5.250 INCHES
BCKXIndicator DesignDIRECT READING
BCKWIndicator Reading TypeMULTIPLE
AMKDIndicator TypeCIRCULAR DIAL
AMQYInstallation DesignBENCH
ALBYUsage DesignEXTERNAL
BCKSVertical Capacity8.000 INCHES
AQYFTest TypeROCKWELL SUPERFICIAL


Back to Top
Back to Top