6640-00-290-6718

STAND,LABORATORY APPARATUS SUPPORT


6640-00-290-6718 (6640002906718, 002906718)
Part Numbers (2 listings): GGS741TYPE1SIZE3 | 14-670 |
Summary

FSG 66 / FSC 6640

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Replacement NSN:

6640-00-440-1200

Replacement Date: 24 Feb 1982

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6640-00-290-6718 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
GGS741TYPE1SIZE34 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberFEDERAL SPECIFICATIONS  81348    CAGE 81348  
GGS741TYPE1SIZE34 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberFEDERAL SPECIFICATIONS  81348    CAGE 81348  
14-6705 - Replaced / Discontinued1 - Incomplete Part NumberFISHER SCIENTIFIC COMPANY L.L.C.  22527    CAGE 22527  
14-6705 - Replaced / Discontinued1 - Incomplete Part NumberFISHER SCIENTIFIC COMPANY L.L.C.  22527    CAGE 22527  
Code Definitions

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6640-00-290-6718 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666640002906718T269-N17190X1APU1 Jan 1963
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Laboratory Equipment and Supplies

002906718

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6640-00-290-6718

T269-N

Federal Item Identification Guide (FIIG_4065)

17190

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6640-00-290-6718 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3KX61KX024 Feb 1982 6640004401200 11 Jan 1982
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Feb 1982

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

6640-00-440-1200

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

11 Jan 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6640-00-290-6718 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6640-00-290-6718 Submit RFQ
MRCDecoded RequirementClear Text Reply
AESHBase MaterialIRON, CAST
BGKBBase Overall Length9.000 INCHES NOMINAL
BNFPBase Overall Width6.000 INCHES NOMINAL
BNJTBase ConstructionRECTANGULAR
ZZZTNondefinitive Spec/Std Data1 TYPE AND 3 SIZE
ADAVOverall Diameter0.438 INCHES NOMINAL
ABHPOverall Length24.000 INCHES NOMINAL
SURFSurface TreatmentUNABLE TO DECODE
BNFTSupport Rod DetachabilityDETACHABLE
BNFWSupport Rod LocationCENTER OF SHORT SIDE OF BASE
BNFRSupport Rod MaterialSTEEL
BNFSSupport Rod Surface TreatmentCOPPER COATED


Back to Top