6640-00-428-9120

INCUBATOR,BACTERIOLOGICAL


6640-00-428-9120 (6640004289120, 004289120)
Part Numbers (3 listings): 28912 | 11-684TYPEF | GGI488 |
Summary

FSG 66 / FSC 6640

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6640-00-428-9120 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
289123 - Design Control Reference2 - Production ItemSP INDUSTRIES INC.  19880      
11-684TYPEF3 - Design Control Reference2 - Production ItemFISHER SCIENTIFIC WORLDWIDE  94480      
GGI4884 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberFEDERAL SPECIFICATIONS  81348    CAGE 81348  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6640-00-428-9120 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666640004289120T269-E17095X1APA01 Jan 1963
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Laboratory Equipment and Supplies

004289120

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6640-00-428-9120

T269-E

Federal Item Identification Guide (FIIG_4065)

17095

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6640-00-428-9120 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZU011 Apr 1991
ZW011 Oct 2009
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6640-00-428-9120 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324KX28912  19880  
332XKXD11-684TYPEF  94480  
3414KXDGGI488  81348   CAGE/81348
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

KX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

X

Document Availability Code (DAC_2640)


DAC not known. Found on U.S. NSNs that were assigned before 1975. Cannot be used for new item assignment, or any maintenance action on older NSNs.

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6640-00-428-9120 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX015 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6640-00-428-9120 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
534Z9ACZF014500X06350APPARATUS-CHEMICAL-LABORATORY
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


534

Water Commodity Code (WRT_CMDTY_CD_9275)


Medical Supplies (not requiring temperature control)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

C

Air Commodity Code (AIR_CMTY_HDLG_9215)


Chemical corps items and all other chemicals not covered in other classifications. When chemical item (as indicated by the DOT Proper Shipping Name) is sensitive as defined in Appendix A Section I of DoD 4500.32-R, Volume I, second position must be from table 85, part 1.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

F

Less Than Truckload (CLAS_RTNG_CD_2770)


150

014500

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

06350

Uniform Freight Classification (UFC_CD_MODF_3040)

APPARATUS-CHEMICAL-LABORATORY

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6640-00-428-9120 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9MYU1EA0
DAS9MYU1OEA0
Code Definitions

S9M

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Troop Support, Director of Medical Material, Philadelphia, PA 19145 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

O

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or economically unserviceable, dispose at organizational level; COAST GUARD: Reparable item. When uneconomically reparable, condemn and dispose at the organizational (user) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose of at organization level; NAVY: Unassigned

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6640-00-428-9120 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKYDAccessory Components And QuantitySET OF HEATING ELEMENTS 1,THERMOMETER 1
BQMJCabinet Inner Wall MaterialSTEEL, CORROSION RESISTING AND NICKEL COPPER ALLOY
BQMHCabinet Outer Wall MaterialSTEEL, CORROSION RESISTING
BHGTCirculation MethodGRAVITY
AQZFControl TypeMAIN SWITCH AND PILOT LIGHT AND THERMOMETER-REGULATOR AND VENTILATOR
ACDCCurrent TypeAC
ACZBFrequency Rating60.0 HERTZ NOMINAL
AZZHHeat Source For Which DesignedINTEGRAL
BDWTHeating MethodELECTRICAL
ZZZTNondefinitive Spec/Std DataD CLASS AND 1 SIZE
ASQJOperating Temp Range In Deg Celsius+30.0/+60.0
BQMROuter Door Insulation FeatureINCLUDED
BQMPOuter Door MaterialSTEEL, CORROSION RESISTING
BQMNOuter Door Quantity1
BCXBOutside Depth22.000 INCHES NOMINAL
AFMWOutside Height28.000 INCHES NOMINAL
ADJVOutside Width25.000 INCHES NOMINAL
BQMWInner Door Mounting MethodHINGE
BQMSInner Door Quantity1
BQMTInner Door MaterialGLASS
AFEFInside Depth14.000 INCHES NOMINAL
AFMQInside Height13.000 INCHES NOMINAL
BLSTInsulated CabinetPROVIDED
ADJTInside Width13.000 INCHES NOMINAL
BQWHMaterial CharacteristicPERFORATED
ANPTPower Rating400.0 WATTS NOMINAL
BGZMShelf AdjustabilityADJUSTABLE
BPYKShelf MaterialSTEEL, CORROSION RESISTING
BGZLShelf Quantity2
FAAZPhaseSINGLE
FEATSpecial FeaturesCONVECTION TYPE; SMALL; FOR REPLACEMENT THERMOMETER,ORDER 6685-00-299-8496
BQWNVacuum ChamberNOT INCLUDED
AMSEVoltage Rating110.0 VOLTS MINIMUM AND 220.0 VOLTS MAXIMUM
BGXHWater JacketNOT PROVIDED


Back to Top
Back to Top