6640-00-440-4832

DISTILLING APPARATUS,LABORATORY


6640-00-440-4832 (6640004404832, 004404832)
Part Numbers (4 listings): GGD465 | 9-018A | 12750A | S27415 |
Summary

FSG 66 / FSC 6640

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6640-00-440-4832 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
GGD4654 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberFEDERAL SPECIFICATIONS  81348    CAGE 81348  
9-018A5 - Replaced / Discontinued2 - Production ItemFISHER SCIENTIFIC WORLDWIDE  94480      
12750A5 - Replaced / Discontinued9 - No Longer UsedCENTRAL SCIENTIFIC CO  11273      
S274155 - Replaced / Discontinued9 - No Longer UsedSARGENT-WELCH SCIENTIFIC CO  64484      
Code Definitions

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6640-00-440-4832 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666640004404832T269-E17191X1APU1 Jan 1963
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Laboratory Equipment and Supplies

004404832

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6640-00-440-4832

T269-E

Federal Item Identification Guide (FIIG_4065)

17191

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6640-00-440-4832 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZH011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6640-00-440-4832 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3414KXDGGD465  81348   CAGE/81348
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

KX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6640-00-440-4832 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX015 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6640-00-440-4832 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6640-00-440-4832 Submit RFQ
MRCDecoded RequirementClear Text Reply
BQLXDistilling Unit Quantity1
AKYDAccessory Components And QuantityCOMPONENTS 1 CONDENSER 1 CONCENTRATOR 1 VAPORATOR 1 HEATING ELEMENT 1 WATER REGULATOR 1 WRENCH,HEXAGONAL
AFPMAssembly FormASSEMBLED
BQWYBleeder DeviceINCLUDED
BQMDBoiler Chamber Overall Diameter6.406 INCHES NOMINAL
BQMFBoiler Chamber Overall Height13.000 INCHES NOMINAL
AFJUCarrying CaseNOT PROVIDED
BQLZCondenser Jacket Overall Height18.000 INCHES NOMINAL
AWLPCondenser TypeOVERHEAD TUBE
ACDCCurrent TypeAC/DC
AQDDFeed TypeCONTINUOUS
ACZBFrequency Rating60.0 HERTZ NOMINAL
BDWTHeating MethodELECTRICAL
MATTMaterialCOPPER ALLOY AND COPPER ALLOY AND COPPER AND STEEL CORROSION RESISTING AND NICKEL ALLOY AND VIRGIN TIN
AAXXMounting TypeLEG
ZZZTNondefinitive Spec/Std Data1 CLASS AND 1 SIZE
BQLQLoad Capacity1.000 GALLONS PER HOUR
BQWXLow Water Automatic Heater Shut-OffNOT INCLUDED
ANPTPower Rating2.6 KILOWATTS NOMINAL
ABFYOverall Depth14.000 INCHES NOMINAL
ABKWOverall Height27.000 INCHES NOMINAL
ABMKOverall Width21.000 INCHES NOMINAL
FAAZPhaseSINGLE
AMSEVoltage Rating110.0 VOLTS NOMINAL AND 220.0 VOLTS NOMINAL
AWCDWater For Which DesignedHARD WATER


Back to Top