6640-00-471-5689

FURNACE,MUFFLE,LABORATORY


6640-00-471-5689 (6640004715689, 004715689)
Part Numbers (3 listings): F-A10525P-1 | 10500-1 | FA10525P-1 |
Summary

FSG 66 / FSC 6640

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 11 Jan 1971

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6640-00-471-5689 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
F-A10525P-13 - Design Control Reference2 - Production ItemTHERMOLYNE CORP  59681      
10500-15 - Replaced / Discontinued1 - Incomplete Part NumberTHERMOLYNE CORP  59681      
FA10525P-15 - Replaced / Discontinued9 - No Longer UsedBARNSTEAD THERMOLYNE CORPORATION  05852      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6640-00-471-5689 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666640004715689T269-E48727X43APAA011 Jan 1971
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Laboratory Equipment and Supplies

004715689

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6640-00-471-5689

T269-E

Federal Item Identification Guide (FIIG_4065)

48727

Item Naming Code (INC_4080)

11 Jan 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6640-00-471-5689 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
FGG4FEE400XD991 Sep 2000
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

X

Nonconsumable Item Material Support Code (NIMSC_0076)


All other conditions.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

99DSOR

Depot Source of Repair Codes (DSOR_0903)


Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6640-00-471-5689 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX010 Nov 1971
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 Nov 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6640-00-471-5689 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SEQ732Z9AHZF014500X06350APPARATUS-CHEMICAL-LABORATORY1
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

Q

Less Than Carload (LCL_CD_2760)


70

732

Water Commodity Code (WRT_CMDTY_CD_9275)


Tools, Hand and Portable, Electric

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

F

Less Than Truckload (CLAS_RTNG_CD_2770)


150

014500

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

06350

Uniform Freight Classification (UFC_CD_MODF_3040)

APPARATUS-CHEMICAL-LABORATORY

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 6640-00-471-5689 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZVU1UEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

U

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6640-00-471-5689 Submit RFQ
MRCDecoded RequirementClear Text Reply
BDWTHeating MethodELECTRICAL
ACDCCurrent TypeAC
AMSEVoltage Rating115.0 VOLTS NOMINAL
ACZBFrequency Rating60.0 HERTZ NOMINAL
FAAZPhaseSINGLE
ANPTPower Rating1680.0 WATTS MAXIMUM
BNDWCooling Coils For Below Room Temp UseNOT INCLUDED
BGXHWater JacketNOT PROVIDED
AFMWOutside Height18.125 INCHES NOMINAL
ADJVOutside Width14.375 INCHES NOMINAL
BCXBOutside Depth12.250 INCHES NOMINAL
AFMQInside Height5.500 INCHES NOMINAL
ADJTInside Width6.500 INCHES NOMINAL
AFEFInside Depth6.625 INCHES NOMINAL
BLSTInsulated CabinetPROVIDED
BQMNOuter Door Quantity1
AKYDAccessory Components And Quantity4 SILICON CONTROLLED RECTIFIER, AUTOMATIC PROPORTIONING SOLID STATE CONTRLLER, RECESSED COUNTER WEIGHT DOOR


Back to Top
Back to Top