6640-00-539-7267

INCUBATOR,BACTERIOLOGICAL


6640-00-539-7267 (6640005397267, 005397267)
Part Numbers (2 listings): XX63-000-00 | XX6300000 |
Summary

FSG 66 / FSC 6640

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 25 Sep 1974

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6640-00-539-7267 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
XX63-000-003 - Design Control Reference2 - Production ItemEMD MILLIPORE CORPORATION  08071      
XX63 000 005 - Replaced / Discontinued2 - Production ItemEMD MILLIPORE CORPORATION  08071      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6640-00-539-7267 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666640005397267T269-E17095X1APU25 Sep 1974
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Laboratory Equipment and Supplies

005397267

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6640-00-539-7267

T269-E

Federal Item Identification Guide (FIIG_4065)

17095

Item Naming Code (INC_4080)

25 Sep 1974

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6640-00-539-7267 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G51000C1 Apr 1991
ZE011 Apr 1991
ZT011 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG C - REFERENCE NUMBER | NSN 6640-00-539-7267 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332475DXX63-000-00  08071  
5249ZDXX63 000 00  08071  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6640-00-539-7267 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX022 Jan 1979
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Jan 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6640-00-539-7267 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
51
Code Definitions

51

Originating Activity Code (ORIG_ACTY_CD_4210)


Environmental Protection Agency, Washington, DC 20406

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6640-00-539-7267 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKYDAccessory Components And QuantityMONITOR RACK 1,THERMOMETER ASSEMBLY 1,ELECTRIC POWER CORD 1,LIGHTER SOCKET ADAPTER 1,EUROPEAN WALL SOCKET ADAPTER 1,BATTERY CLIP ADAPTER 1,14.4 VOLT INDICATOR LAMP 1,PKG OF 5 CARTRIDGE FUSES 1
BQMJCabinet Inner Wall MaterialPLASTIC, ACRYLIC
BQMHCabinet Outer Wall MaterialPLASTIC
BHGTCirculation MethodANY ACCEPTABLE
AQZFControl TypePILOT LIGHT AND TEMPERATURE
ACDCCurrent TypeAC/DC
AZZHHeat Source For Which DesignedINTEGRAL
BDWTHeating MethodELECTRICAL
ASQJOperating Temp Range In Deg Celsius+27.0 TO 60.0
BQMROuter Door Insulation FeatureINCLUDED
BQMPOuter Door MaterialPLASTIC
BQMNOuter Door Quantity1
BQMTInner Door MaterialPLASTIC
BQMSInner Door Quantity1
BLSTInsulated CabinetNOT PROVIDED
BQWHMaterial CharacteristicEXPANDED
BGZMShelf AdjustabilityNOT ADJUSTABLE
BPYKShelf MaterialSTEEL, STAINLESS
BGZLShelf Quantity1
ABFYOverall Depth10.500 INCHES NOMINAL
ABKWOverall Height11.500 INCHES NOMINAL
ABMKOverall Width15.500 INCHES NOMINAL
FEATSpecial FeaturesPORTABLE FIELD TYPE
BQWNVacuum ChamberNOT INCLUDED
AMSEVoltage Rating6.000 VOLTS NOMINAL AND 12.000 VOLTS NOMINAL AND 24.000 VOLTS NOMINAL AND 115.000 VOLTS NOMINAL AND 230.000 VOLTS NOMINAL
BGXHWater JacketPROVIDED


Back to Top