6640-01-074-7826

LIQUID BATH,ELECTRIC


6640-01-074-7826 (6640010747826, 010747826)
Part Numbers (8 listings): 27-50-420-5 | 21530-046 | W-5783-2 | 13-874-204 | S-84905-10 | K-2/RD | 335-141 | W3237-2 |
Summary

FSG 66 / FSC 6640

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 6 Apr 1979

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6640-01-074-7826 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
27-50-420-53 - Design Control Reference2 - Production ItemEPPENDORF NORTH AMERICA, INC.  13487      
21530-0465 - Replaced / Discontinued2 - Production ItemVWR SCIENTIFIC  08474      
W-5783-25 - Replaced / Discontinued2 - Production ItemSP INDUSTRIES INC  2A303      
13-874-2045 - Replaced / Discontinued2 - Production ItemFISHER SCIENTIFIC COMPANY L.L.C.  22527    CAGE 22527  
S-84905-105 - Replaced / Discontinued2 - Production ItemSARGENT-WELCH SCIENTIFIC CO  64484      
K-2/RD5 - Replaced / Discontinued2 - Production ItemEPPENDORF NORTH AMERICA, INC.  13487      
335-1415 - Replaced / Discontinued9 - No Longer UsedCURTIN MATHESON SCIENTIFIC INC  15481      
W3237-25 - Replaced / Discontinued9 - No Longer UsedBAXTER HEALTHCARE CORP  22353      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6640-01-074-7826 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666640010747826T269-J20327X43APU6 Apr 1979
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Laboratory Equipment and Supplies

010747826

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6640-01-074-7826

T269-J

Federal Item Identification Guide (FIIG_4065)

20327

Item Naming Code (INC_4080)

6 Apr 1979

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6640-01-074-7826 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G51000C1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG C - REFERENCE NUMBER | NSN 6640-01-074-7826 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
432451D27-50-420-5  13487  
452451DK-2/RD  13487  
452451D13-874-204  22527   CAGE/22527
52451W-5783-2  2A303  
452451DS-84905-10  64484  
452451D21530-046  08474  
459451B335-141  15481  
459451BW3237-2  22353  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

51

Reference Number Action Activity Code (RNAAC_2900)


Environmental Protection Agency, Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6640-01-074-7826 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59706 Apr 1979
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Apr 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6640-01-074-7826 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
51
Code Definitions

51

Originating Activity Code (ORIG_ACTY_CD_4210)


Environmental Protection Agency, Washington, DC 20406

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6640-01-074-7826 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKYDAccessory Components And QuantityDUPLEX PUMP 1; THERMOMETER 2; CORD,ELECTRICAL 1; MANUAL,INSTRUCTION 1
BNDSAccuracy Range-0.01/+0.01 DEG CELSIUS
BNDQAgitatorNOT INCLUDED
BBLTCapacity Rating1.000 GALLONS NOMINAL
BNDWCooling Coils For Below Room Temp UseINCLUDED
BNDPHeating Element Frequency Rating60.0 HERTZ NOMINAL
BBJZHeating Element Current TypeAC
BKGKHeating Element Quantity1
BKGRHeating Element Voltage Rating115.0 VOLTS NOMINAL
BBTGHeating Element Wattage In Watts750.0
AXPYOpening Quantity1
AFGAOperating Temp Range-10.0/+150.0 DEG CELSIUS
BNDFReservoir MaterialSTEEL, STAINLESS
SHPEShapeSQUARE
FEATSpecial Features0.2 HP COMPRESSOR
FAAZPhaseSINGLE
BNDYPilot LightNOT INCLUDED
BNDMTest Tube RackNOT INCLUDED
BNDXThermometer OpeningPROVIDED
BNDRThermoregulatorINCLUDED


Back to Top