6640-01-652-9923

GENERATOR,HYDROGEN


6640-01-652-9923 (6640016529923, 016529923)
Part Number (1 listing): 100-000-0017
Summary

FSG 66 / FSC 6640

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 9 Mar 2016

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6640-01-652-9923 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
100-000-00173 - Design Control Reference2 - Production ItemFLIR SYSTEMS, INC.  64869      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6640-01-652-9923 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666640016529923T396-G13795X43APAA09 Mar 2016
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6640

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Laboratory Equipment and Supplies

016529923

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6640-01-652-9923

T396-G

Federal Item Identification Guide (FIIG_4065)

13795

Item Naming Code (INC_4080)

9 Mar 2016

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6640-01-652-9923 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A102000ECN1 Mar 2016
F8SQ000ECN1 Mar 2016
MS22000ECN1 Mar 2016
NJQ4000ECN1 Mar 2016
SC0100PECN1 Mar 2016
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

0

Nonconsumable Item Material Support Code (NIMSC_0076)


DLIS File Conversion Code. This code was assigned by DLIS to existing wholesale interservice supply support agreement (WISSA) type recording (LOA 8D) during initial file conversion program. This code is reassigned to code 1, 2, 3, 5, 6 or 8 upon completion of item review. The SICA CMD will reflect the SOS/SOSM and AAC compatible with the PICA. The PICA will not be entered in the DAAS IMM field.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

P

Nonconsumable Item Material Support Code (NIMSC_0076)


Total depot maintenance is being accomplished by commercial contract.

CNDSOR

Depot Source of Repair Codes (DSOR_0903)


Contract, Contiguous United States (CONUS)


FLIS - SEG C - REFERENCE NUMBER | NSN 6640-01-652-9923 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ100-000-0017  64869  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG G - FREIGHT DATA | NSN 6640-01-652-9923 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
XJ
Code Definitions

XJ

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ USSOCOM, MacDill AFB, FL 33621-5323

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 6640-01-652-9923 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAH9DJU0LKT0
DNH9DJU0HKT0
DFH9DJU0SKT0
DJH9DJU0KT0
DMH9DJU0LKT0
Code Definitions

H9D

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Special Operations Forces Support Activity (SOFSA), BLDG 220, 5749 Briar Hill Rd, Lexington, KY 40516-9721

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

L

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: Disposal is not authorized below wholesale/specialized repair activity level; MARINE CORPS: Reparable item. Repair, condemnation, and disposal not authorized below depot/specialized repair activity level; NAVY: Local stock items or items pending national stock number assignment

KT

Unit of Issue (UI_3050)


Kit - A collection of related items issued as a single item of supply, such as the tools, instruments, repair parts, instruction sheets and often supplies typically carried in a box or bag. Also includes selected collections of equipment components, tools, and/or materials for the repair, overhaul or modification of equipment. Use only when the term “kit” is a part of the item name.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

S

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DJ

Service / Agency Code (MOE_CD_2833)


HQ United States Special Operations Command (HQ USSOCOM)

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6640-01-652-9923 Submit RFQ
MRCDecoded RequirementClear Text Reply
FEATSpecial FeaturesHYDROGEN GENERATOR FOR USE WITH GAS CHROMATOGRAPH MASS SPECTROMETER (GCMS) PRODUCTS. PRODUCES HYDROGEN GAS TO OPERATE GCMS. KIT INCLUDES POWER CORD, USER MANUAL, SILICA GEL, DEIONIZER BAGS, DESICANT CAP TOOL, 1/8 IN REFRIGERATION-GRADE COPPER LINE WITH 1/4 IN AND 1/8 IN SWAGELOK FITTINGS FOR CONNECTION TO THE GRIFFIN GC/MS, AND A FITTING THAT CONNECTS THE GENERATOR TO A 0.375 IN (3/8 IN) TYGON TUBE, WHICH IS INSERTED INTO A DEIONIZED WATER CONTAINER OR WATER SUPPLY. REF: 664001D1. H9D/SOCOM LOGISTICS HELP DESK: CML (859)293-3114; DSN: 745-3114; TOLL FREE: 888-763-7259; EMAIL: LOGISTICSHELPDESK@SOFSA.MIL.


Back to Top
Back to Top