Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
M3971/2-2 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-DTL-3971 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
10N-G3 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | SANGAMO WESTON INC | 07446 | ![]() |
10N-G3-H | 5 - Replaced / Discontinued | 9 - No Longer Used | SANGAMO WESTON INC | 07446 | ![]() |
MIL-M-3971 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
MS16971-2 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY STANDARDS | 96906 | ![]() |
911800077 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOCKHEED MARTIN CORPORATION | 11530 | ![]() |
465-1051-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOCKHEED MARTIN CORPORATION | 11530 | ![]() |
M3971/2-6 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
31EX | 5 - Replaced / Discontinued | 9 - No Longer Used | LEE CO THE | 31356 | ![]() |
JBTE31-EX | E - Replace Reference Number | 8 - Replacement NSN | LEE CO THE | 31356 | ![]() |
1170238 | E - Replace Reference Number | 8 - Replacement NSN | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
635ES100AA0008A | E - Replace Reference Number | 8 - Replacement NSN | METERMASTER INC | 25497 | ![]() |
HD654-99999 | E - Replace Reference Number | 8 - Replacement NSN | DE JUR-AMSCO CORP | 28281 | ![]() |
632E | E - Replace Reference Number | 8 - Replacement NSN | CRAMER CO DIVISION OF CHESTNUT GROUP | 14907 | ![]() |
A12574 | E - Replace Reference Number | 8 - Replacement NSN | VDO CONTROL SYSTEMS INC | 82227 | ![]() |
1170238 | E - Replace Reference Number | 8 - Replacement NSN | ARMA DIV | 03848 | ![]() |
10635000 | E - Replace Reference Number | 8 - Replacement NSN | HENLEY MARINE INC | 20227 | ![]() |
NA602789A001 | E - Replace Reference Number | 8 - Replacement NSN | LOCKHEED MARTIN CORPORATION | 56232 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6645 | 010577987 | T134-R | 08066 | X | 1 | A | N | A | 0 | 19 Mar 1978 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Jul 1993 | |||||||||||||||||||||||||||||
G860 | 0 | 0 | C | 5 Sep 1994 | ||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
YA01 | 1 Dec 2001 | |||||||||||||||||||||||||||||
ZR01 | 1 Apr 2002 | |||||||||||||||||||||||||||||
ZU01 | 1 Oct 2002 | |||||||||||||||||||||||||||||
WP01 | 1 Oct 2003 | |||||||||||||||||||||||||||||
MC41 | MC04 | 1 | T | Z | PA | 1 Sep 2006 | ||||||||||||||||||||||||
N9BG | N9GD | 1 | T | Z | HD | GT | KE | HD | 1 Sep 2006 | |||||||||||||||||||||
BGX1 | BCX1 | 1 | T | 1 Sep 2006 | ||||||||||||||||||||||||||
C911 | C006 | 1 | T | 1 Feb 2013 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | 2 | 3 | CX | D | M3971/2-2 | 81349 | ![]() | ||||
4 | 1 | E | ZZ | MIL-DTL-3971 | 81349 | ![]() | ||||||
1 | 5 | 1 | 6 | CX | D | 10N-G3 | 07446 | ![]() | ||||
4 | 5 | 9 | 6 | CX | B | 10N-G3-H | 07446 | ![]() | ||||
3 | 5 | 9 | 5 | ZZ | B | 31EX | 31356 | ![]() | ||||
4 | 5 | 9 | 5 | 9Z | B | 465-1051-1 | 11530 | ![]() | ||||
1 | 5 | 9 | 6 | CL | B | 911800077 | 11530 | ![]() | ||||
1 | 5 | 9 | 3 | CX | D | MIL-M-3971 | 81349 | ![]() | ||||
5 | 9 | 3 | CX | B | M3971/2-6 | 81349 | ![]() | |||||
5 | 9 | 5 | SB | B | MS16971-2 | 96906 | ![]() | |||||
3 | E | 8 | 1 | ZZ | D | 1170238 | 03848 | ![]() | ||||
3 | E | 8 | 6 | 9Z | B | A12574 | 82227 | ![]() | ||||
4 | E | 8 | 4 | 9Z | D | 632E | 14907 | ![]() | ||||
E | 8 | 1 | HD | 10635000 | 20227 | ![]() | ||||||
E | 8 | 5 | HD | 635ES100AA0008A | 25497 | ![]() | ||||||
3 | E | 8 | 5 | ZZ | B | HD654-99999 | 28281 | ![]() | ||||
4 | E | 8 | 5 | ZZ | D | JBTE31-EX | 31356 | ![]() | ||||
3 | E | 8 | 6 | 9Z | D | NA602789A001 | 56232 | ![]() | ||||
3 | E | 8 | 1 | ZZ | D | 1170238 | 10001 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
DLIS-K, Battle Creek, MI 49037-3084
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645001717101 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 11 May 1970 | 6645001719251 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 0 | 11 May 1970 | 6645001719579 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645001719605 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 0 | 31 Jul 1964 | 6645001719606 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 0 | 31 Jul 1964 | 6645001719607 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645001719609 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645001719610 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 5 Jan 1976 | 6645002627448 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645002858781 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 7 Jan 1976 | 6645004333075 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645005313722 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645005421734 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645005561888 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645006638109 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 0 | 31 Jul 1964 | 6645007088536 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 11 May 1970 | 6645007360476 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 11 May 1970 | 6645008165337 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645008469206 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 0 | 7 Jan 1976 | 6645008516654 | 26 Aug 1989 |
1 | CX | 0 | 3 | CX | 1 | 23 Aug 1989 | 6645008804893 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 31 Jul 1964 | 6645008934190 | 26 Aug 1989 |
1 | CX | 0 | 3 | TU | 1 | 11 Feb 1972 | 6645009309356 | 26 Aug 1989 |
1 | CX | 0 | 3 | CX | 1 | 23 Aug 1989 | 6645011054646 | 26 Aug 1989 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 657 | Z | 9 | A | V | Z | Q | 136760 | X | 68830 | METERS-ELEC-WATT-HOUR-USED |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Instruments, Electric Meter
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
70
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 0.7 lbs | 0.090 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | E | Q | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BHLR | Electrical Movement Type | SYNCHRONOUS MOTOR |
BHLQ | Background Color | BLACK BACKGROUND ON HR WHEELS,WHITE BACKGROUND ON TENTHS WHEEL |
ARBR | Body Depth | 3.000 INCHES MAXIMUM |
ABPM | Body Diameter | 2.625 INCHES MAXIMUM |
ADTV | Case Material | ANY ACCEPTABLE |
ACDC | Current Type | AC |
AQCS | Hermetic Protection | NOT PROVIDED |
BHLN | Maximum Measurement | 99999.90 |
ANSX | Measurement Unit | HOURS |
ALGC | Mounting Configuration | THREE 0.150 IN. DIA MTG HOLES ON 1.580 IN. RADIUS SPACED 120 DEG APART |
APTE | Mounting Flange Diameter | 3.500 INCHES MAXIMUM |
AXGY | Mounting Method | FLUSH |
AAXX | Mounting Type | FLANGE |
AQEC | Movement Type | ELECTRICAL |
ZZZT | Nondefinitive Spec/Std Data | A GRADE AND II TYPE |
APTT | Operating Frequency | 60.0 HERTZ NOMINAL |
AMKD | Indicator Type | DRUM REGISTER |
BHLP | Marking Color | WHITE NUMERALS FOR HOURS,BLACK NUMERALS FOR TENTHS |
BHCH | Reset Feature | NOT PROVIDED |
AXEA | Smallest Increment Indicated | 0.10 |
APQB | Unit Type | MOUNTED |
AMSE | Voltage Rating | 120.0 VOLTS NOMINAL |
AARA | Terminal Quantity | 2 |
AARB | Terminal Type | SOLDER |