Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
324C06D3CR1A01X | 3 - Design Control Reference | 9 - No Longer Used | AUTOMATIC TIMING AND CONTROLS CO | 04864 | ![]() |
324C06D3CR1A01X | C - Advisory Reference | 1 - Incomplete Part Number | AUTOMATIC TIMING & CONTROLS, INC. | 1RGT9 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6645 | 012297749 | T270-D | 04842 | X | K | A | N | A | 0 | 6 Apr 1986 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C056 | C165 | 1 | P | 1 Jun 2010 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The rights to use the data needed to purchase this part from additional sources are not owned by the Government and cannot be purchased. Valid AMCs: 1, 2, 3, 4 and 5.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
C | 1 | 3 | ZZ | 9F | 324C06D3CR1A01X | 1RGT9 | ![]() |
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
USA
CAGE Status Change
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 6 Apr 1986 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
Commanding Officer, USCG Surface Force Logistics Center, Code 028, Mil Stop 25, 2401 Hawkins Point Road, Baltimore, MD 21226-5000
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions; MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions; NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
U.S. Coast Guard
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ARAE | Automatic Electric Circuit Control Switch | NOT INCLUDED |
AQZF | Control Type | AUTOMATIC |
ACDC | Current Type | AC |
AQZD | Dc Operated Clutch | NOT INCLUDED |
ARCK | Dial Minimum Graduation | 2 SEC |
AGAV | End Item Identification | USED IN CONTROLLER MODEL MFC-500M/1 ONBOARD 210 FT WMEC COAST GUARD VESSELS |
FREQ | Frequency In Hertz | 60.0 |
APHE | Operation Method | SYNCHRONOUS MOTOR |
APPS | Timer Type | ELECTRICAL |
ARCR | Independently Operated Clock | NOT INCLUDED |
ARAJ | Interval Expiration Signalling Device | NOT INCLUDED |
APZS | Reset Type | ANY ACCEPTABLE |
ABFY | Overall Depth | 4.750 INCHES NOMINAL |
ABKW | Overall Height | 9.500 INCHES NOMINAL |
ABMK | Overall Width | 7.250 INCHES NOMINAL |
ARCE | Time Indicator Total Capacity | 120 SEC |
AWJN | Unpackaged Unit Weight | 2.000 POUNDS |
ELEC | Voltage In Volts | 120.0 |