Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
6A | 3 - Design Control Reference | 2 - Production Item | APPLIED BIOSYSTEMS, LLC | 46555 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6650 | 004398350 | T271-D | 17266 | X | 1 | A | N | U | 1 Jan 1963 |
Optical Instruments, Test Equipment, Components and Accessories
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | CX | 6A | 46555 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Richmond, Richmond, VA 23297-5000
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | BF | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
D | 744 | Z | 9 | A | M | Z | D | 058110 | X | 33110 | OPTICAL-GOODS-OR-INSTRUMENTS-NOI |
200
Optical Goods
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKYD | Accessory Components And Quantity | ADAPTER,TEST TUBE,10 BY 75 MM 1; ADAPTER,TEST TUBE,19 BY 150 MM 1; FILTER,CALIBRATING 1; LAMP,INCANDESCENT,EXCITER 4; LAMP,INCANDESCENT,GA LVANOMETER 4; MANUAL,TECHNICAL 1; TEST TUBE,10 BY 75 MM 48; TEST TUBE,19 BY 150 MM 48 |
AEXR | Battery Quantity | 1 |
AEXS | Battery Type | WET |
AEXQ | Battery | INCLUDED |
ANLJ | Battery Voltage Rating In Volts | 6.00 |
AMPS | Current Rating In Amps | 100.0 |
AFSS | Design Current Rating In Amps | 1.02 NOMINAL AND 4.20 NOMINAL |
ANEH | Design Designation | DAY |
AEWV | Lamp Base Style | DOUBLE CONTACT BAYONET CANDELABRA AND SINGLE CONTACT CANDELABRA PREFOCUS |
AEWT | Lamp Bulb Shape Style | G GLOBULAR AND T TUBULAR |
AEWU | Lamp Bulb Size Designator | G-6 AND T-8 |
AFAX | Lamp Industry Number | GE82 AND GE4.2A/T8/SCP |
AEWZ | Lamp Transparency | CLEAR AND CLEAR |
AEWR | Lamp Quantity | 1 AND 1 |
AEWX | Lamp Voltage Rating In Volts | 8.0 AND 8.5 |
BMML | Quartz Prism | NOT INCLUDED |
ATEQ | Scale Type | FIXED |
BMMY | Slit Adjustability | NONADJUSTABLE |
BMMM | Trickle Charger | INCLUDED |
BMMK | Wavelength Range | +400.0/+700.0 MILLIMICRONS |