Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
XL10TGQW | 3 - Design Control Reference | 2 - Production Item | LEICA INC | 78039 | ![]() |
XL10TGQW | 5 - Replaced / Discontinued | 2 - Production Item | AMERICAN OPTICAL CO | 02622 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6650 | 009131854 | T271-C | 09176 | X | 1 | Q | N | A | 1 Jan 1960 |
Optical Instruments, Test Equipment, Components and Accessories
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G510 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
FGG4 | FEE4 | 0 | 0 | X | D | 99 | 1 Sep 2000 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
All other conditions.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | BF | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 732 | Z | 9 | A | H | Q | D | 058110 | X | 33110 | OPTICAL-GOODS-OR-INSTRUMENTS-NOI | 1 |
77.5
Tools, Hand and Portable, Electric
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Extremely fragile items including delicate instruments.
200
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKYD | Accessory Components And Quantity | BASE ILLUMINATOR W/VAR. TRANSFORMER 1 |
BMMD | Body Tube Accessroy Slot | NOT PROVIDED |
BMLW | Body Tube Position | INCLINED |
BMMB | Body Tube Analyzer | NOT INCLUDED |
BMMC | Body Tube Bertrand Lens | NOT PROVIDED |
BMLZ | Body Tube Interchangeability Feature | NOT PROVIDED |
AFJU | Carrying Case | NOT PROVIDED |
BPFD | Condenser Adjustability | ADJUSTABLE |
BMSZ | Cover Glass Correction Collar | NOT PROVIDED AND NOT PROVIDED |
APGF | Design Type | RESEARCH MODEL |
BMST | Disc Insert Usage Design | PROVIDED |
BPFY | Eyepiece Magnification | 10 |
BPFW | Eyepiece Quantity | 1 |
BCTD | Focusing Type | FIXED |
BPFP | Funnel Stop Design Feature | NOT PROVIDED AND PROVIDED |
BPFR | Mounted Micrometer Scale | NOT PROVIDED |
BMSR | Mounted Cross Hairs | NOT PROVIDED |
BMLT | Nonstereoscopic Type | TRINOCULAR |
BPFK | Nosepiece Design | TURRET |
BPFL | Nosepiece Place Quantity | 4 |
BMTB | Numeric Aperture | 1.25 |
BPFQ | Objective Iris Diaphragm | NOT PROVIDED AND NOT PROVIDED |
BPFM | Objective Quantity | 3 AND 1 |
BMTH | Objective Type | DRY AND OIL IMMERSION |
ALBY | Usage Design | BIOLOGY |
BPFF | Iris Diaphragm Type | NONCENTERABLE |
ABRY | Length | 175.0 MILLIMETERS NOMINAL |
BMSX | Lens Coating Feature | COATED AND COATED |
BLGP | Lens Type | ACHROMATIC AND ACHROMATIC |
BLPR | Magnification | 4.0X NOMINAL AND 10.0X NOMINAL AND 45.0X NOMINAL AND 100.0X NOMINAL |
BPFG | Polarizer | NOT PROVIDED |
ABGL | Width | 137.0 MILLIMETERS NOMINAL |
BPFB | Stage Calibration Facility | GRADUATED SCALE |
BMMG | Stage Material | ALUMINUM |
BMMF | Stage Shape | RECTANGULAR |
BMMH | Stage Type | MECHANICAL |
BPFC | Substage Condenser Design | ANY ACCEPTABLE |