6650-01-569-5643

TELESCOPE,MINIATURE


6650-01-569-5643 (6650015695643, 015695643)
Part Number (1 listing): 8502M7
Summary

FSG 66 / FSC 6650

DEMIL: A

DEMIL INT: 4

HMIC: N

Date Created: 3 Dec 2008

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6650-01-569-5643 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
8502M73 - Design Control Reference2 - Production ItemELTEC INSTRUMENTS, INC.  9F547      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6650-01-569-5643 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666650015695643A2390077777X41ANAA03 Dec 2008
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6650

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Optical Instruments, Test Equipment, Components and Accessories

015695643

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6650-01-569-5643

A23900

Federal Item Identification Guide (FIIG_4065)

77777

Item Naming Code (INC_4080)

3 Dec 2008

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

1

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name does not exist.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6650-01-569-5643 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZN011 Dec 2008
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6650-01-569-5643 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD8502M7  9F547  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6650-01-569-5643 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59703 Dec 2008
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Dec 2008

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6650-01-569-5643 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
80
Code Definitions

80

Originating Activity Code (ORIG_ACTY_CD_4210)


NASA Marshall Space Flight Center, Marshall Space Flight Center, AL 35812-0001

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6650-01-569-5643 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABHPOverall Length3.750 INCHES NOMINAL
ADAVOverall Diameter1.250 INCHES NOMINAL
HUESColorGREEN
FEATSpecial FeaturesPASSIVE NON-CONTACT MONITORING;LOW POWER CONSUMPTION;HIGH ENVIRONMENTALNOISE REJECTION;WATER RESISTANT;NO INTERFERENCE BETWEEN UNITS;FAST RESPONSE;INDOOR/OUTDOOR OPERATION;NOMINAL RANGEOF 195 FEET;3-15 VDC SUPPLY VOLTAGE;REFRACTIVE, PLANO-CONVEX OPTICS;TWO CHANNEL LITHIUM TANTALATE PYROELECTRIC DETECTORS;ANALOG OUTPUT
CXCYPart Name Assigned By Controlling AgencyIR-EYE DIRECTIONAL MINIATURE PASSIVE INFRARED THERMAL TELESCOPE


Back to Top
Back to Top