6660-01-020-3765

ALTIMETER-BAROMETER,ANEROID


6660-01-020-3765 (6660010203765, 010203765)
Part Number (1 listing): 570-23932-005
Summary

FSG 66 / FSC 6660

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 29 Apr 1976

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6660-01-020-3765 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
570-23932-0053 - Design Control Reference2 - Production ItemKOLLSMAN, INC.  89944    CAGE 89944  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6660-01-020-3765 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666660010203765T206-G12872XM6ANU29 Apr 1976
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6660

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Meteorological Instruments and Apparatus

010203765

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6660-01-020-3765

T206-G

Federal Item Identification Guide (FIIG_4065)

12872

Item Naming Code (INC_4080)

29 Apr 1976

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6660-01-020-3765 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6660-01-020-3765 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3229Z570-23932-005  89944   CAGE/89944
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6660-01-020-3765 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597029 Apr 1976
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Apr 1976

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6660-01-020-3765 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
85D653Z9ASZD057690X32860ALTIMETERS-IN-BOXES
Code Definitions

85

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Energy, West Mifflin, PA 15122

D

Less Than Carload (LCL_CD_2760)


200

653

Water Commodity Code (WRT_CMDTY_CD_9275)


Musical Instruments

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

S

Air Commodity Code (AIR_CMTY_HDLG_9215)


Office, School, and Household Supplies/Equipment including Office Machines, Furniture/Stationary, Films, Synthetic/Special Training Films, Non-Hazardous Household Cleaning Products, Non-Hazardous Personal Hygiene Products, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

057690

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

32860

Uniform Freight Classification (UFC_CD_MODF_3040)

ALTIMETERS-IN-BOXES

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6660-01-020-3765 Submit RFQ
MRCDecoded RequirementClear Text Reply
ANFQAltitude Scale GraduationFEET
ANFTAltitude Scale Smallest Increment20.0 FEET
ANGCBarometer Scale GraduationINCHES OF MERCURY
ANGEBarometer Scale Smallest Increment0.010 INCHES OF MERCURY
AKAEMaximum Operating Altitude Rating50000.0 FEET


Back to Top