Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
IM19PD | 3 - Design Control Reference | 2 - Production Item | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
K151 | 5 - Replaced / Discontinued | 2 - Production Item | GE MEDICAL SYSTEMS | F0179 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6665 | 002633943 | T132-B | 07833 | X | 1 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Mar 2008 | |||||||||||||||||||||||||||||
ZF01 | 1 May 2015 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | AC | 0 | 19 Aug 1985 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
U.S. Army Chemical Research, Development and Engineering Center Aberdeen Proving Ground, MD 21010-5423
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
W | 658 | Z | 9 | A | H | Z | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI | 1 |
Rating Variable
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APPN | Accuracy In Percent | NOT RATED |
AFJU | Carrying Case | NOT PROVIDED |
ADTV | Case Material | ALUMINUM |
ADTY | Case Surface Treatment | ANODIZED |
AMRX | Detecting Element Type | IONIZATION CHAMBER |
APPQ | Energy Dependence Rating | NOT RATED |
ADJH | Mounting Method | ANY ACCEPTABLE |
ADAV | Overall Diameter | 0.500 INCHES NOMINAL |
AGAV | End Item Identification | TYPE AN/PDR-3A |
AKWA | Joint Electronics Type Designation System Item Name | RADIACMETER |
AKWB | Joint Electronics Type Designation System Item Type Number | TYPE IM-19/PD |
AMKD | Indicator Type | OPTICAL QUARTZ FIBER ELECTROMETER |
ALSF | Internal Battery Accommodation | NOT INCLUDED |
APCB | Portability | PORTABLE |
APPJ | Radiation Range Per Hour | +0.0 TO 10.0 ROENTGENS |
AMRM | Radiation Type And Function | GAMMA RAYS MEASURES AND X-RAYS MEASURES |
ABHP | Overall Length | 4.281 INCHES NOMINAL |
CSBH | Voltage In Volts And Current Type | 180.0 DC |