Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
470301 | 3 - Design Control Reference | 2 - Production Item | MINE SAFETY APPLIANCES COMPANY | 55799 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6665 | 011614811 | T132-A | 17495 | X | 1 | A | P | A | A | 0 | 6 Sep 1983 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FXX4 | FEE4 | 0 | 0 | X | D | 99 | 1 Jun 2000 | |||||||||||||||||||||||
ZX01 | 1 Jan 2014 |
Not Established
All other conditions.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | SB | 470301 | 55799 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | HD | 0 | 3 Jun 1985 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | 652 | Z | 9 | A | V | Z | D | 058280 | X | 33190 | SCIENTIFIC-INSTRUMENTS-NOI |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Instruments, Scientific
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
200
No Variation. NMFC and UFCC Match.
Oklahoma City Air Logistics Center, 3001 Staff Drive, Tinker AFB, OK 73145-3303
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Unclassified
1
AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AMRX | Detecting Element Type | ELECTROCHEMICAL |
AMRZ | Detecting Element Detachability | INTEGRAL |
AMSE | Voltage Rating | 120.0 VOLTS NOMINAL |
AMSL | Preamplifier | NOT INCLUDED |
AMSM | Photomultiplier | NOT INCLUDED |
ADTV | Case Material | STEEL |
APPF | Cable | NOT INCLUDED |
AMSN | Connector | INCLUDED |
ABKW | Overall Height | 13.500 INCHES NOMINAL |
FEAT | Special Features | MONITOR CAN BE WALL MOUNTED; SEALED CASE; HAS VISUAL ALARM, BRIGHT RED,LOCATED ON FRONT PANEL; AUDIBLE ALARM EMITS SHRILL NOISE; ALSO SOUNDS IF SENSOR DISCONNECTED FOR 30 SECONDS OR MORE WHILE UNIT IS ON AND POWERED; AMBER PILOT LIGHT INDICATES UNIT IS ON AND POWERED; HORN SILENCE/RESET SWITCH CANCELS AUDIBLE HORN ALARM; SPDT WARNING RELAY FOR EXTERNAL USE-TRIP POINT MAY BE SET FOR ANY RANGE VALUE; TWO SPDT ALARM RELAYS, ONE LATCHING, ONE NONLATCHING; POWER SELECTOR SWITCH, PERMITS USE OF 115 OR 120 VAC POWER, PREWIRED 115 VAC POWER CORD SUPPLIED; INCLUDES CIRCUIT BREAKER RESET; FLOW FAILURE SWITCH ACTIVATES AUDIO AND VISUAL ALARM WHEN FLOW TO MONITOR INTERRUPTED; 3 WAY VALVE ALLOWS INTRODUCTION OF CALIBRATION GAS; INCLUDES PRESSURE RELIEF VALVE; RANGE 0-100 PPM CO; WEIGHT 18 LBS |
FTLD | Functional Description | CARBON MONOXIDE AIR LINE MONITOR THAT CONTINUOUSLY MONITORS COMPRESSED AIR LINES FOR CARBON MONOXIDE; PROVIDES DIRECT LINEAR READOUT OF CO CONCENTRATION, ACTUATES ALARMS WHEN PREDETERMINED LEVEL REACHED OR SAMPLE FLOW TO THE UNIT STOPS |