Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
51-8073 | 3 - Design Control Reference | 2 - Production Item | BACHARACH, INC. | 05083 | ![]() |
MIL-I-38715 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6665 | 012948859 | A23800 | 18532 | S | 4 | 3 | F | Y | B | A | 0 | 23 Feb 1989 |
The item is a non-aviation Critical Safety Item (CSI) whose failure will result in serious damage to equipment or serious injury or death to personnel.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (SME) — Demilitarization instructions to be furnished by the Item/Technical Manager.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Nov 1994 | |||||||||||||||||||||||||||||
ZU01 | 1 Aug 1995 | |||||||||||||||||||||||||||||
ZA01 | 9 Aug 1995 | |||||||||||||||||||||||||||||
ZC01 | 1 Jun 1996 | |||||||||||||||||||||||||||||
ZP01 | 1 Jul 1996 | |||||||||||||||||||||||||||||
YB01 | 1 May 1997 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
YA01 | 1 Jul 2001 | |||||||||||||||||||||||||||||
A739 | A720 | 2 | G | 1 | D | 00 | AM | 1 Sep 2001 | ||||||||||||||||||||||
FGG4 | 2 | G | F | D | FR | 1 Sep 2001 | ||||||||||||||||||||||||
NSGS | NSES | 2 | G | 1 | D | 00 | 1 Sep 2001 | |||||||||||||||||||||||
WP01 | 1 Sep 2004 | |||||||||||||||||||||||||||||
ZR01 | 1 Dec 2007 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
ZX01 | 1 Jan 2014 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Exception Item (End Item of Equipment). This code identifies SICA managed end items of equipment assigned to another service PICA that is responsible for the wholesale logistics support functions of single submitter of cataloging data, acquisition and disposal authority. Supply support requirements will be submitted by the SICA to the PICA on Military Interdepartmental Purchase Requests (MIPRs) unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store, and issue functions in support of SICA activities and has retained depot repair capability where applicable. Retention of depot maintenance capability for end items of equipment requires documented justification by the SICA to the PICA via JLC Form 19. If PICA and SICA cannot reach an agreement the documentation will be forwarded to the joint MISMOs for a decision. The SICA Catalog Management Data (CMD) will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the Defense Automatic Addressing System Integrated Materiel Manager (DAAS IMM) field.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
An activity within the Air Force is providing depot maintenance support.
Consumable Item or Ammunition
Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA
U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 1 | 4 | ZZ | MIL-I-38715 | 81349 | ![]() |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 23 Feb 1989 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | F | 653 | G | 9 | A | H | D | F | 058240 | X | 33170 | RECORDING-DEVICES-GAUGES-METERS-NOI |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
150
Musical Instruments
Nonflammable compressed gas, UN class 2 (nonflammable gas label; Except: (1) oxygen which requires an oxidizer label, and (2) fluorine which requires poison and oxidizer labels)
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.
No Variation. NMFC and UFCC Match.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
US Army Aviation and Missile Command (Air), ATTN: AMSMI-LC-MM-C, Redstone Arsenal, AL 35898-5230
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)
Department of the Navy
Department of the Army
Department of the Air Force
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | 000 | 38.0 lbs | 28in x 25in x 13in | 5.266 cu ft | 32.0 lbs | 24in x 21in x 9in |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | GF | H | ED | 00 | B | 00 | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
MIL-PRF-26514, Type I, Class 2, Grade B, flexible polyurethane foam, medium load range
2 inches thick
ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.
No requirement.
Unit container provides level B packing protection.
No special marking
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AJJW | Component Quantity | 15 |
CRTL | Criticality Code Justification | FEAT |
RDAL | Reference Data And Literature | T.O. 11H5-35-1 |
CXCY | Part Name Assigned By Controlling Agency | ALARM SYSTEM,COMBUSTIBLE GAS AND OXYGEN INDICATOR,AUTOMATIC |
FEAT | Special Features | INTERNAL RECHARGEABLE SEALED LEAD ACID BATTERY;DETECTS FOLLOWING GASSES AND VAPORTS: JP-4, JP-5, JP-8, PF-1, JP-10, PR-148, AVIATION GAS 100-130 OCTANE, EHTYL ALCHOHOL, HYDROGEN, BENZENE, METHANE, HEXANE, PENTANE AND HEPTANE; DETECTION RANGE 0-5 OR 0-50 PERCENT LEL COMBUSTIBLES AND 0-25 PERCENT OXY;THE COMBUSTIBLE SENSOR AND MAIN PRINTED CIRCUIT BOARD OF INDICATOR CONTAIN ESD DEVICES |
ALCD | Usage Design | DETECTS TOXIC AND COMBUSTIBLE LEVELS OF COMBUSTIBLE GASSES AND COMBUSTIBLE VAPORS |
AJKC | Supply Items And Quantities | ITEM INCLUDES CARRYING CASE 1;METHANE CALIBRATION TANK 1;15 FT HOSE ASSY 1;SAMPLE LINE KIT 1;230 VAC CHARGER CORD 1;12 VDC CHARGER CORD 1;DRYING TUBE 1;CARRYING STRAP 1;PROBE ASSEMBLY 1;OXY CELL ASSY 1;REGULATOR ASSY 1;15 FT HOSE ASSY 1;HYDROGEN CALIBRATION TANK 1;INDICATOR AND ALARM 1 |