6665-01-657-7518

DETECTOR,GAS


6665-01-657-7518 (6665016577518, 016577518)
Part Number (1 listing): GASCHECK5000IS
Summary

FSG 66 / FSC 6665

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 29 Aug 2016

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6665-01-657-7518 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
GASCHECK 5000IS3 - Design Control Reference2 - Production ItemION SCIENCE AMERICAS L.L.C.  3HV77      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6665-01-657-7518 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666665016577518T132-A37401X43APA029 Aug 2016
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6665

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Hazard-Detecting Instruments and Apparatus

016577518

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6665-01-657-7518

T132-A

Federal Item Identification Guide (FIIG_4065)

37401

Item Naming Code (INC_4080)

29 Aug 2016

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6665-01-657-7518 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Aug 2016
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6665-01-657-7518 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDGASCHECK 5000IS  3HV77  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6665-01-657-7518 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZH
Code Definitions

ZH

Originating Activity Code (ORIG_ACTY_CD_4210)


Republic of Korea

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6665-01-657-7518 Submit RFQ
MRCDecoded RequirementClear Text Reply
APPFCableNOT INCLUDED
ADTVCase MaterialANY ACCEPTABLE
AMSNConnectorNOT INCLUDED
AMRZDetecting Element DetachabilityDETACHABLE
CXCYPart Name Assigned By Controlling AgencyGASCHECK IS HANDHELD LEAK DETECTOR
AMSMPhotomultiplierNOT INCLUDED
AMSLPreamplifierNOT INCLUDED
FEATSpecial FeaturesDETECTS ALMOST ANY KNOWN GAS OR GAS MIXTURE; PARTICULARLY SENSITIVE TO AMMONIA, ARGON, BUTANE, HELIUM, HYDROGEN AND SF6;SIMPLE, ONE HANDED OPERATION;LARGE, CLEAR LCD BACK LIT DISPLAY FOR EASY VIEWING;GRAPHICAL ICON MENU;CONVENIENTLY CALIBRATED AGAINST HELIUM


Back to Top