Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
724TYPEC4 | 3 - Design Control Reference | 9 - No Longer Used | SOLARTRON ELECTRONICS INC | 65092 | |
CD100927 | 5 - Replaced / Discontinued | 9 - No Longer Used | SOLARTRON ELECTRONICS INC | 65092 | |
724TYC4 | 5 - Replaced / Discontinued | 9 - No Longer Used | SOLARTRON ELECTRONICS INC | 65092 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6680 | 002126418 | A271A0 | 20241 | X | 4 | 9 | A | N | U | 1 Jan 1963 |
Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
YA01 | 1 Jan 2002 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | CX | 0 | 20 Jan 1979 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Q | 590 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI | 1 |
70
Generators and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPP | Electrical Resistance | 200.0 OHMS |
BDJD | Accuracy Range In Percent | -1.0/+1.0 |
BFLQ | Calibration Speed In Rpm | 1000.0 |
BKPC | Calibration Voltage Output Type In Volts | 6.0 AC |
CWGL | Current Rating In Amps | 0.001 SINGLE OUTPUT |
ACDC | Current Type | DC OUTPUT |
AXHR | Mounting Facility Type And Quantity | 1 THREADED COUPLING |
AXGY | Mounting Method | SWIVEL NUT COUPLING |
AAJU | Overall Length | 5.375 INCHES |
CWCS | Length Of Shaft From Housing | 0.500 INCHES SINGLE END |
CWFX | Rotor Speed Rating In Rpm | 200.0 LOW FULL LOAD AND 2000.0 HIGH FULL LOAD |
AAJT | Overall Height | 5.160 INCHES |
AAJV | Overall Width | 3.000 INCHES |
FEAT | Special Features | EQUIPPED W/DRIVE FITTING,W/NAVY WATERTIGHT CABLE CONNECTOR |
TTQY | Terminal Type And Quantity | 1 RECEPTACLE |