6680-00-261-4978

CALIBRATOR,ACCELEROMETER


6680-00-261-4978 (6680002614978, 002614978)
Part Number (1 listing): S15000
Summary

FSG 66 / FSC 6680

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 27 Jun 1973

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6680-00-261-4978 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
S150003 - Design Control Reference9 - No Longer UsedLING ELECTRONICS INC  06510      
S150003 - Design Control Reference9 - No Longer UsedLING ELECTRONICS INC  06510      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 6680-00-261-4978 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666680002614978T145-C36933X43ANAA027 Jun 1973
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6680

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments

002614978

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6680-00-261-4978

T145-C

Federal Item Identification Guide (FIIG_4065)

36933

Item Naming Code (INC_4080)

27 Jun 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6680-00-261-4978 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX611 Nov 1978
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

11 Nov 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6680-00-261-4978 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SE
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6680-00-261-4978 Submit RFQ
MRCDecoded RequirementClear Text Reply
FEATSpecial FeaturesSHAKER; CONSISTS OF A HIGH PERFORMANCE ELECTRODYNAMIC SHAKER DRIVEN BY A DIRECT COUPLED SOLID STATE POWER AMPLIFIER; PROVIDES A SINE FORCE OUTPUT OF 15000 LBS LIMITED BY AN ACCELERATION OF 100 G'S, A VELOCITY OF 45 INCHES PER SECOND OR A DISPLACEMENT OF 0.800 INCHES PEAK TO PEAK; USABLE FREQUENCY 1 HZ TO 3000 HZ; RANDOM VIBRATION FORCE OUTPUT A MINIMUM OF 13000 LBS; POWER 260 KVA AT 440 VAC 3 PHASE, 5 KVA AT 120 VAC SINGLE PHASE, 60 HZ


Back to Top
Back to Top