6680-00-581-2283

INDICATOR,LIQUID QUANTITY


6680-00-581-2283 (6680005812283, 005812283)
Part Numbers (2 listings): 162-099-929 | MILG7818 |
Summary

FSG 66 / FSC 6680

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6680-00-581-2283 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
162-099-9293 - Design Control Reference9 - No Longer UsedAVIEN INC  97485      
MILG78184 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6680-00-581-2283 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666680005812283A533Y003377XM3ANU1 Jan 1963
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6680

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments

005812283

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6680-00-581-2283

A533Y0

Federal Item Identification Guide (FIIG_4065)

03377

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6680-00-581-2283 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU
ZU011 Apr 1991
Code Definitions

FLIS - SEG G - FREIGHT DATA | NSN 6680-00-581-2283 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
J652Z9ABZJ121570X61770GAGES-AIR-LIQUID-LEVEL-PRESSURE1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


J

Less Than Carload (LCL_CD_2760)


100.2

652

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Scientific

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

121570

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

61770

Uniform Freight Classification (UFC_CD_MODF_3040)

GAGES-AIR-LIQUID-LEVEL-PRESSURE

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6680-00-581-2283 Submit RFQ
MRCDecoded RequirementClear Text Reply
ASKZElectrical Connection Identifying NumberAND10066A-20-27P
ASKXElectrical Connection Quantity1
BNHZAccuracy Rating1000.0 POUNDS SINGLE INDICATOR SINGLE SCALE
AFRAContact Quantity14
AKSFContact TypePIN
ACDCCurrent TypeAC
ACZBFrequency Rating400.0 HERTZ NOMINAL
AWHHIllumination Color Generation MethodFLUORESCENCE
ABRYLength5.234 INCHES NOMINAL
ABFNScale Marking And Surface FinishLETTERS FLUORESCENT AND NUMERALS FLUORESCENT AND LINED INCREMENTS FLUORESCENT
FAAZPhaseTWO


Back to Top
Back to Top