| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| LA OAL 15.39 METRES | 3 - Design Control Reference | 2 - Production Item | JOWA USA, INC | 6F198 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 66 | 6680 | 014971294 | T179-J | 22251 | X | 4 | 6 | A | N | A | A | 0 | 9 May 2002 |
Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZK01 | 1 May 2002 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | 4 | 9Z | D | LA OAL 15.39 METRES | 6F198 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | CX | 0 | 12 May 2002 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| MATT | Material | PLASTIC |
| AGAV | End Item Identification | TANK LEVEL & DRAFT GAUGING SYSTEM |
| ZZZV | Fsc Application Data | NHA PN 7100003-016M |
| FTLD | Functional Description | USED FOR WATER APPLICATIONS, INCLUDING FRESH AND SALT WATER, MUNICIPAL WASTEWATER, SEWAGE, AND WATER-BASED SLURRIES AND SUSPENSIONS WITH TEMPERATURES UP TO 158 DEG F |
| SUPP | Supplementary Features | SENSOR NOT SUITED FOR USE IN CHEMICALS, SOLVENTS, OR PETROLEUM, IN HIGH VAPOR-PRESSURE MATERIALS, OR UNDER CRYOGENIC OR HIGH-LEVEL NUCLEAR RADIATION CONDITIONS; TEMPERATURE RANGE 5 TO 158 DEG F; WETTED MATERIALS MYLAR, ACRYLIC AND GLASS-FILLED POLYPROPYLENE, SLIP NUT CHROME PLATED BRASS; ACTIVE HELIX STARTS 12 IN FROM SENSOR ZERO, EXTENDS TO APPROX 1.6 IN FROM SENSOR BOTTOM; HELIX RESOLUTION ONE QUARTER INCH; ACTUATION DEPTH NOMINAL 5 INCH HEAD OF WATER, OFFSET AT CALIBRATION; SENSOR WEIGHT 5.5 LB PLUS .15 LB/FT |
| ABHP | Overall Length | 15.39 MILLIMETERS NOMINAL |
| FEAT | Special Features | ALL ELECTRIC RESISTANCE-TAPE SENSOR FOR STABLE OUTPUT, NO MOVING PARTS TO STICK OR BREAK; TANK TOP MOUNTED FOR EASY INSTALLATION; 5 MINUTE FILTER CHANGE EVERY 24 TO 48 MONTHS; COMBINED LEVEL AND TEMPERATURE CAPABILITY; HIGH RESOLUTION RESISTANCE HELIX AND GOLD-ON-GOLD ELECTRIC CONTACTS FOR ONE QUARTER TURNS RESOLUTION AND LONG TERM CONTACT STABILITY; THE SENSOR JACKET IS MULTI-LAYER, PRINCIPALLY MYLAR POLYESTER AND PROTECTED ON THREE SIDES WITH AN EXTRUDED GLASS-FILLED POLYPROPYLENE BUMPER CHANNEL |