Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MS24569-1 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY STANDARDS | 96906 | ![]() |
MIL-I-27209 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
B588-10-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | SIMMONDS PRECISION PRODUCTS, INC. | 89305 | ![]() |
DST17-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | CARLETON LIFE SUPPORT SYSTEMS INC. | 99251 | ![]() |
8DJ100LAC1 | 5 - Replaced / Discontinued | 9 - No Longer Used | AMETEK, INC. | 97424 | ![]() |
502BL3B | 5 - Replaced / Discontinued | 9 - No Longer Used | HORIZON AEROSPACE LLC DBA MAGNETICS | 35918 | ![]() |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6685 | 006845176 | A533Y0 | 03395 | X | 4 | 3 | Q | P | A | A | 0 | 1 Jan 1963 |
Pressure, Temperature, and Humidity Measuring and Controlling Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
FXX4 | FEE4 | 1 | T | F | E | FT | 1 Aug 2000 | |||||||||||||||||||||||
NAXS | NAXP | 1 | T | 4 | E | FT | GG | 1 Sep 2000 | ||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
YB01 | 1 Sep 2009 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
An activity within the Air Force is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Depot Reparable Component. (Type I Temporary). This code identifies SICA managed depot reparable components assigned to another service PICA that is responsible for the logistics functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store and issue functions for SICA activities. This code is temporarily assigned to items which have not completed Phase II item review processing. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Oklahoma City Air Logistics Center (OC-ALC), Tinker AFB, OK
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 4 | 1 | 4 | SE | D | MS24569-1 | 96906 | ![]() | ||||
4 | 5 | 9 | 9 | SB | B | 8DJ100LAC1 | 97424 | ![]() | ||||
1 | 5 | 9 | 9 | SB | B | DST17-1 | 99251 | ![]() | ||||
5 | 9 | 9 | TU | B | B588-10-1 | 89305 | ![]() | |||||
4 | 5 | 9 | 9 | SB | B | 502BL3B | 35918 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is of the type for which an indication of document availability is not required.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | CX | 0 | 2 Aug 1999 |
An item authorized for procurement that has not yet been subject to item standardization.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
652 | 3 | 9 | A | V | Q | F | 058240 | X | 33170 | RECORDING-DEVICES-GAUGES-METERS-NOI |
Instruments, Scientific
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
Extremely fragile items including delicate instruments.
150
No Variation. NMFC and UFCC Match.
Oklahoma City Air Logistics Center, 3001 Staff Drive, Tinker AFB, OK 73145-3303
RESTRICTED REQUISITIONING-SPECIAL INSTRUCTIONS APPLY (NON-STOCKED ITEMS) Indicates stock number has been assigned to a generic item for use in bid invitations, allowance lists, etc., against which no stocks are ever recorded. Requisitions will be submitted only in accordance with IMM/Service requisitioning procedures. (This code will be used, when applicable, in conjunction with Phrase Code S (Stock as NSN(s)). It is considered applicable for use when a procurement source(s) becomes available. The Phrase Code S and the applicable ?stock as? NSN(s) will then be applied for use in stock, store and issue actions.)
Unclassified
1
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
NAVY: (1) Iram program intensive management reparables (2) material (expendable ordnance) requiring lot and serial-# control but which is reported by serial-# only.
Department of the Air Force
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | S | A | 51 | 1 | 000 | 3.5 lbs | 12.7in x 8.4in x 8.4in | 0.524 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | X | NR | 00 | B | 03 | Q | F | M |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | 000 | 3.3 lbs | 8.3in x 8.3in x 12.5in | 0.498 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | NR | 00 | B | 17 |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Secondary Inventory Control Activity (SICA)
Heated General Purpose – Heated 40 F and above
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
No requirement
MIL-DTL-17667, neutral wrapping paper
As required to protect the item or elements of the package
PPP-B-1672, Type I, vertical star cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
Mehod 50
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type I, vertical star cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
Reusable container
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ASKZ | Electrical Connection Identifying Number | MS33678-18-9P |
ASKX | Electrical Connection Quantity | 1 |
ACYN | Ac Voltage Rating | 115.0 VOLTS NOMINAL |
AFRA | Contact Quantity | 9 |
AKSF | Contact Type | PIN |
ACDC | Current Type | AC |
ABMZ | Diameter | 2.000 INCHES NOMINAL |
ACZB | Frequency Rating | 400.0 HERTZ NOMINAL |
ASKN | Individual Marking | TEMP DEG C X 100 |
ABRY | Length | 5.875 INCHES NOMINAL |
ASST | Pointer Type | INDICATING SINGLE POINTER |
AMNL | Presentation Type | DIAL |
APSK | Scale Range | +100.0/+1200.0 DEG CELSIUS SINGLE INDICATOR SINGLE SCALE |
CXCY | Part Name Assigned By Controlling Agency | SERVO TEMPERATURE INDICATOR; INDICATOR TEMPERATURE THERMOCOUPLE,SELF BALANCING POTENTIOMETER TYPE |
FAAZ | Phase | SINGLE |
FEAT | Special Features | INDICATOR HAS LINEAR SCALES WITH A MAIN DIAL AND A SUBDIAL; POWER CONSUMPTION 10 VOLT AMPERES; OPERATES ON SIGNALS GENERATED BY CHROMEL ALUMEL THERMOCOUPLES; CASE HERMETICALLY SEALED AND PER MS33639; FINISH DURABLE DULL BLACK; DIAL INTERGRALLY LIGHTED PER MIL-L-25467; INDICATOR PROVIDED WITH A POWER OFF WARNING; 5 V LIGHTING; WEIGHT 1.5 LBS |
SUPP | Supplementary Features | TECH ORDER 5E6-3-42-14 |