6685-00-802-9294

GAGE,PRESSURE,DIAL INDICATING


6685-00-802-9294 (6685008029294, 008029294)
Part Number (1 listing): 83D
Summary

FSG 66 / FSC 6685

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1960

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6685-00-802-9294 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
83D3 - Design Control Reference1 - Incomplete Part NumberLIFTEC INC  72100      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6685-00-802-9294 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666685008029294T179-B07428XLAPU1 Jan 1960
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6685

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Pressure, Temperature, and Humidity Measuring and Controlling Instruments

008029294

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6685-00-802-9294

T179-B

Federal Item Identification Guide (FIIG_4065)

07428

Item Naming Code (INC_4080)

1 Jan 1960

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

L

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference - Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6685-00-802-9294 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZR011 Dec 2007
ZU011 Apr 2008
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6685-00-802-9294 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3314SED83D  72100  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SE

Reference Number Action Activity Code (RNAAC_2900)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6685-00-802-9294 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX123 Jul 1996
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

23 Jul 1996

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6685-00-802-9294 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6685-00-802-9294 Submit RFQ
MRCDecoded RequirementClear Text Reply
BGKYActuating Element MaterialPHOSPHOR BRONZE
APCMActuation TypeDIAPHRAGM
APCSAdjustabilityADJUSTABLE
BHMDBezel TypeSNAP-ON
ABKGBolt Circle Diameter3.031 INCHES NOMINAL
ADTVCase MaterialDRAWN STEEL
ADTYCase Surface TreatmentENAMEL, BLACK
BHMGConnection Size0.250 IN. NPT DIA
BGRYConnection LocationBACK, CENTER
ASMMConnection Quantity1
BHMKConnector Type VentNOT PROVIDED
AWLSConnection TypeEXTERNAL
ARCHDial Size2-1/2 IN. DIA
ANBJGraduation Unit1.0 POUNDS PER SQUARE INCH
MATTMaterialSTEEL, DRAWN
ABTBMounting Hole Diameter0.156 INCHES NOMINAL
ABTJMounting Hole Quantity3
AXGYMounting MethodFLUSH PANEL
ASSSPointer ColorBLACK
ASSTPointer TypeINDICATING
BHMFProtective Crystal MaterialPLASTIC
ZZZYReference Number Differentiating CharacteristicsAS DIFFERENTIATED BY SCALE DATA,DIAL DATA,CASE DATA
BGKSScale AccuracyPORM 1 PCT FULL SCALE
BGKZScale Inscription/Background ColorBLACK FIGURES ON WHITE BACKGROUND
AQFZScale NamePRESSURE
AWAGScale Smallest Increment0.125 POUNDS
ATEQScale TypeSINGLE
APSKScale Range+0.000 TO 10.000 POUNDS PRESSURE PER SQUARE INCH
ABFYOverall Depth1.250 INCHES NOMINAL
ADAVOverall Diameter3.469 INCHES NOMINAL
SFTTSurface TreatmentENAMEL


Back to Top