6685-00-850-3784

THERMOMETER,INDICATING,CAPILLARY TUBE AND BULB


6685-00-850-3784 (6685008503784, 008503784)
Part Number (1 listing): 60C
Summary

FSG 66 / FSC 6685

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1962

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6685-00-850-3784 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
60C3 - Design Control Reference1 - Incomplete Part NumberWINTERS INSTRUMENTS  35786      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6685-00-850-3784 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666685008503784A2760007419XN9APU1 Jan 1962
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6685

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Pressure, Temperature, and Humidity Measuring and Controlling Instruments

008503784

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6685-00-850-3784

A27600

Federal Item Identification Guide (FIIG_4065)

07419

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

N

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6685-00-850-3784 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6685-00-850-3784 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
315CX60C  35786  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6685-00-850-3784 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59801 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6685-00-850-3784 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
J653Z5AMYZ000000X00000NO-NMFC-FREIGHT-DESCRIPTION
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


J

Less Than Carload (LCL_CD_2760)


100.2

653

Water Commodity Code (WRT_CMDTY_CD_9275)


Musical Instruments

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

5

Special Handling Code (SP_HDLG_CD_9240)


Protected (Pilferable)

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

M

Air Commodity Code (AIR_CMTY_HDLG_9215)


Medical supplies, equipment, samples records, etc.

Y

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.

Z

Less Than Truckload (CLAS_RTNG_CD_2770)


No Rating

000000

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

00000

Uniform Freight Classification (UFC_CD_MODF_3040)

NO-NMFC-FREIGHT-DESCRIPTION

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6685-00-850-3784 Submit RFQ
MRCDecoded RequirementClear Text Reply
BKCZActive Portion Diameter0.500 INCHES NOMINAL
BKCYActive Portion Length6.000 INCHES NOMINAL
BKCMActuating MediumMERCURY
BKCXBulb Connection TypeTHREADED
CSYHBulb Overall Length7.000 INCHES NOMINAL
BKCTBulb Quantity1
BKCWBulb TypePLAIN RIGID
ABKJCase Diameter7.750 INCHES NOMINAL
BHMCCase TypeDUSTPROOF
ASSPDial Diameter6.000 INCHES NOMINAL
BLQGFlexible Tube Length120.000 INCHES NOMINAL
MATTMaterialIRON METER CASE
MATTMaterialSTEEL CORROSION RESISTING BULB
AFFLMounting Bolt Circle Diameter7.000 INCHES NOMINAL
AXHRMounting Facility Type And Quantity1 FLUSH AND 3 HOLE
BLQFIndicator Connection MethodFLEXIBLE TUBE
CSYJPointer/Pen Type And Quantity1 INDICATING SINGLE
ZZZYReference Number Differentiating CharacteristicsAS DIFFERENTIATED BY SCALE READING DATA,BULB DATA,AND CASE DATA
BGKZScale Inscription/Background ColorBLACK MARKING ON WHITE BACKGROUND
CSYGScale Measurement Range+0.000/+150.000 DEG FAHRENHEIT
AWAGScale Smallest Increment1.0 DEG FAHRENHEIT
ATEQScale TypeCONCENTRIC DIAL
ABKWOverall Height2.375 INCHES NOMINAL
AEBVUnthreaded Mounting Hole Diameter0.281 INCHES NOMINAL


Back to Top