Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
60C | 3 - Design Control Reference | 1 - Incomplete Part Number | PALMER INSTRUMENTS, INC. | 23471 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6685 | 008570149 | A27600 | 07419 | X | 4 | 3 | A | P | U | 29 Apr 1972 |
Pressure, Temperature, and Humidity Measuring and Controlling Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DGX1 | DCX1 | 5 | U | CX | 1 Feb 2005 |
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The cost to the Government to breakout this part and acquire it competitively has been determined to exceed the projected savings over the life span of the part. Valid AMCs: 1, 2, 3, 4 and 5.
Defense Supply Center Richmond, Richmond, VA 23297-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 1 | 4 | SE | D | 60C | 23471 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | J | 652 | Z | 9 | A | H | Z | W | 058360 | Z | 33220 | THERMOMETERS-O-THAN-CLINICAL |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
100.2
Instruments, Scientific
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 31 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | JA | LC | X | EC | 00 | E | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Waterproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
A-A-3174, plastic sheet, polyolefin, 2 mil
PPP-C-795, Class 1, cellular plastic film cushioning
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BKCZ | Active Portion Diameter | 1.438 INCHES NOMINAL |
BKCY | Active Portion Length | 6.000 INCHES NOMINAL |
BKCM | Actuating Medium | MERCURY |
BKCX | Bulb Connection Type | THREADED |
BKCT | Bulb Quantity | 1 |
CSYH | Bulb Overall Length | 7.250 INCHES NOMINAL |
BKCW | Bulb Type | PLAIN RIGID |
ABKJ | Case Diameter | 7.750 INCHES NOMINAL |
BHMC | Case Type | DUSTPROOF |
ASSP | Dial Diameter | 6.000 INCHES NOMINAL |
BLQG | Flexible Tube Length | 60.000 INCHES NOMINAL |
MATT | Material | ALUMINUM OVERALL |
AFFL | Mounting Bolt Circle Diameter | 7.000 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 1 FLUSH AND 3 HOLE |
BLQF | Indicator Connection Method | FLEXIBLE TUBE |
CSYJ | Pointer/Pen Type And Quantity | 1 INDICATING SINGLE |
BGKZ | Scale Inscription/Background Color | BLACK FIGURES ON WHITE BACKGROUND |
AWAG | Scale Smallest Increment | 1.0 DEG FAHRENHEIT |
ATEQ | Scale Type | CONCENTRIC DIAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.281 INCHES NOMINAL |