Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
GGP725TYPE3 | 2 - Definitive Specification or Standard Document | 2 - Production Item | FEDERAL SPECIFICATIONS | 81348 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6685 | 008921643 | T134-K | 09725 | X | 1 | A | P | U | 1 Jan 1962 |
Pressure, Temperature, and Humidity Measuring and Controlling Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 2005 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | CX | 0 | 12 Jun 1969 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
F | 651 | Z | 9 | A | M | Z | F | 056680 | X | 32570 | DENTAL-MEDICAL-SURG-INST-R-MACHINE | 1 |
150
Instruments, Medical and Surgical
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKYD | Accessory Components And Quantity | ILLUMINATION LAMPS 2; THERMOMETERS 2; WICKING 1 |
BDHW | Calibration Accuracy Rating | PORM 0.3 FOR 0 DEG AND ABOVE |
ANWE | Carrying Case Material | ANY ACCEPTABLE |
BHGS | Circulation Type | FORCED |
BHGT | Circulation Method | FAN |
BHHD | Cistern Material | PLASTIC |
HUES | Color | RED, LIGHT |
BHGX | Engraved Thermometer Stem | INCLUDED |
AZKB | Fan Motor Current Type | DC |
AWEC | Graduation Interval | 10.0 DEG |
BHHH | Mounting Panel Tables | NOT PROVIDED |
BHHG | Mounting Shelter | NOT INCLUDED |
AFGA | Operating Temp Range | +35.0/+150.0 DEG FAHRENHEIT |
BBST | Magnifying Lens | NOT INCLUDED |
BHHF | Sling Handle | NOT INCLUDED |
ABKW | Overall Height | 2.000 INCHES NOMINAL |
ABHP | Overall Length | 10.000 INCHES NOMINAL |
ABMK | Overall Width | 4.500 INCHES NOMINAL |
AMSE | Voltage Rating | 4.500 POUNDS PER HOUR WET |
BHHB | Thermometer Mounting Material | STEEL, STAINLESS |
BHGZ | Thermometer Mounting Method | BACKPLATE |
BHGY | Thermometer Filling Type | SPIRIT |
BHGW | Thermometer Quantity | 2 |