6685-01-016-7342

THERMOSTAT,FLOW CONTROL


6685-01-016-7342 (6685010167342, 010167342)
Part Number (1 listing): 1096X075
Summary

FSG 66 / FSC 6685

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 20 Feb 1976

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6685-01-016-7342 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1096X0753 - Design Control Reference2 - Production ItemAMOT CONTROLS CORPORATION  94607      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6685-01-016-7342 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666685010167342T121-C16516X1APU20 Feb 1976
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6685

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Pressure, Temperature, and Humidity Measuring and Controlling Instruments

010167342

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6685-01-016-7342

T121-C

Federal Item Identification Guide (FIIG_4065)

16516

Item Naming Code (INC_4080)

20 Feb 1976

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6685-01-016-7342 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
ZN011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6685-01-016-7342 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
13249ZD1096X075  94607  
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6685-01-016-7342 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6CX020 Jan 1979
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

20 Jan 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6685-01-016-7342 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
94J657Z9ABZJ188340X33230VALVES-THEMOSTATIC-NOI-THEMOSTATS
Code Definitions

94

Originating Activity Code (ORIG_ACTY_CD_4210)


NASA Dryden Flight Research Facility, Edwards AFB, CA 93523-0273

J

Less Than Carload (LCL_CD_2760)


100.2

657

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Electric Meter

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

188340

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

33230

Uniform Freight Classification (UFC_CD_MODF_3040)

VALVES-THEMOSTATIC-NOI-THEMOSTATS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6685-01-016-7342 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADQUFlow Control DevicePOPPET
ADJHMounting MethodANY ACCEPTABLE
AWTMOpening Temp Rating70.0 DEG FAHRENHEIT NOMINAL
AWTNOperating Temp Rating75.0 DEG FAHRENHEIT NOMINAL
AWPAThermostat TypeWAX PELLET
AGWMLargest Outside Diameter2.870 INCHES MINIMUM AND 2.878 INCHES MAXIMUM
ABKWOverall Height5.500 INCHES NOMINAL
ALCDUsage DesignOIL OR WATER COOLING CONTROL
AMSDValve Travel Distance0.375 INCHES MINIMUM
AWTPSpring Operated Pressure ReliefNOT PROVIDED


Back to Top