Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
70323-1 | 3 - Design Control Reference | 2 - Production Item | THERMO ELECTRIC COMPANY INC. | 99195 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6685 | 010486411 | A31700 | 05662 | X | 4 | 3 | Q | P | A | A | 0 | 30 Sep 1977 |
Pressure, Temperature, and Humidity Measuring and Controlling Instruments
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
ZT01 | 1 Feb 1998 | |||||||||||||||||||||||||||||
FGG4 | 3 | H | X | E | 99 | 1 Sep 2000 | ||||||||||||||||||||||||
ZB01 | 1 Apr 2003 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 2008 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
All other conditions.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | SB | D | 70323-1 | 99195 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | TU | 0 | 1 Dec 1997 |
An item authorized for procurement that has not yet been subject to item standardization.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | M | 72E | Z | 9 | A | H | Z | F | 058240 | X | 33170 | RECORDING-DEVICES-GAUGES-METERS-NOI | 1 |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
85
Engineer and Material Handling Equipment, Test/Tool sets and Equipment
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
150
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Naval Inventory Control Point, Philadelphia, PA 19111-5098
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
NAVY: Special Program Reparables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)
Department of the Navy
Department of the Air Force
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 51 | 1 | 000 | 63.0 lbs | 26.5in x 26.5in x 20.5in | 8.331 cu ft | 53.0 lbs | 20.5in x 17.3in x 16.5in |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | NA | X | ED | 00 | B | 19 | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.
No requirement.
Unit container provides level B packing protection.
Method 50 reusable container
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ATJK | Power Source | EXTERNAL |
AFXE | Maximum Voltage Rating In Volts | 115.0 AC |
FREQ | Frequency In Hertz | 400.0 |
FAAZ | Phase | SINGLE |
CHQP | Maximum Overall Length | 14.000 INCHES |
CHQQ | Maximum Overall Width | 18.000 INCHES |
CHQR | Maximum Overall Height | 8.000 INCHES |
CKRD | Sensing Element Type And Location | THERMOCOUPLE REMOTE |
ASXT | Operating Range | 0 TO 400 DEG F, 0 TO 200 DEG C |
FEAT | Special Features | UPPER PART OF THE CASE CONTAINS THE POWER CABLE ASSEMBLY, THERMOCOUPLES, AND THERMOCOUPLE EXTENSION CABLE; LOWER SECTION OF CASE HAS THE CONTROL UNIT INSTRUMENT PANEL, RELAY AMPLIFIER ASSEMBLY, RELAY PANEL AND MEASURING CIRCUIT PANEL; ITEM IS PORTABLE; PYROMETER INDICATES TEMP IN FARENHEIT AND CENTIGRADE; CONTROL THERMOCOUPLE SAFETY FEATURE LIMITS THE TEMP NOT TO EXCEED 375 DEG F (190 DEG C); WEIGHT 30 LBS |
AGAV | End Item Identification | STRUCTURAL REPAIR KIT |
FCLS | Functional Classification | JJ-6 |
FTLD | Functional Description | DESIGNED TO CONTROL HEATING BLANKETS DURING AIRCRAFT HONEYCOMB REPAIR |
RTSE | Relationship To Similar Equipment | 6685-00-766-0237 |
RDAL | Reference Data And Literature | T.O. 33A29-2-2-1 |
NTRD | Entry Date | 80-10-21 |
CXCY | Part Name Assigned By Controlling Agency | TEMPERATURE CONTROL SET |