6695-00-320-8312

INDICATOR,SYMBOL INDICATING


6695-00-320-8312 (6695003208312, 003208312)
Part Numbers (3 listings): 108-59 | 9A34 | 3750008 |
Summary

FSG 66 / FSC 6695

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 11 Nov 1973

Unit Weight: None

Unit Size:

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6695-00-320-8312 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
108-593 - Design Control Reference9 - No Longer UsedAPPLIED MAGNETICS INC  02374      
9A345 - Replaced / Discontinued2 - Production ItemTRANSICOIL LLC  25805      
37500085 - Replaced / Discontinued9 - No Longer UsedAIRCRAFT INSTRUMENTS COMPANY  09959    CAGE 09959  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6695-00-320-8312 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666695003208312A534R020814X1ANAA011 Nov 1973
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6695

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Combination and Miscellaneous Instruments

003208312

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6695-00-320-8312

A534R0

Federal Item Identification Guide (FIIG_4065)

20814

Item Naming Code (INC_4080)

11 Nov 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6695-00-320-8312 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6695-00-320-8312 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
33959ZD108-59  02374  
3522ZGD9A34  25805  
35959ZB3750008  09959   CAGE/09959
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6695-00-320-8312 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6CX01 May 1978
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 May 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6695-00-320-8312 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZGJ652ZZAVZJ121570X61770GAGES-AIR-LIQUID-LEVEL-PRESSURE
Code Definitions

ZG

Originating Activity Code (ORIG_ACTY_CD_4210)


Germany

J

Less Than Carload (LCL_CD_2760)


100.2

652

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Scientific

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

V

Air Commodity Code (AIR_CMTY_HDLG_9215)


Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

121570

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

61770

Uniform Freight Classification (UFC_CD_MODF_3040)

GAGES-AIR-LIQUID-LEVEL-PRESSURE

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 6695-00-320-8312 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APZZ1
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XZZO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6695-00-320-8312 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationNSNS 6680-00-593-3306 AND 6680-00-790-0082 LIQUID OXYGEN INDICATOR SETS TECH ORDER 15X4-3-1-114
CWJKCase MaterialSTEEL
AFRAContact Quantity3
AKSFContact TypeTERMINAL LUG
ACDCCurrent TypeDC
ACYRDc Voltage Rating22.0 VOLTS MINIMUM AND 30.0 VOLTS MAXIMUM
CXQHDial Outside Diameter0.385 INCHES NOMINAL
ABMZDiameter0.375 INCHES NOMINAL
AEJNDistance Between Mounting Facility Centers0.686 INCHES NOMINAL
HGTHHeight0.380 INCHES NOMINAL
ANRLMounting Arrangement StyleTWO HOLE/STUD
AXHRMounting Facility Type And Quantity2 SLOTTED HOLE
ABVGMounting Slot Length0.445 INCHES NOMINAL
ABTDMounting Slot Width0.125 INCHES NOMINAL
ABRYLength1.156 INCHES NOMINAL
ASKQMarking Color Specific UsePOWER-OFF SIGNAL AND POWER-ON SIGNAL
AMNLPresentation TypeDRUM DIAL AND WINDOW
FEATSpecial FeaturesOPERATING TIME 0.1 SECOND OR LESS;COIL RESISTANCE 750 OHMS;INDICATOR CASE TIN-PLATED FOR CORROSION RESISTANCE;OPERATINIG TEMP RANGE MINUS 55 DEG C TO 90 DEG C;MINIMUM INSULTATION RESISTANCE 20 MEG. OHMS AT 500 VOLTS DC WINDING TO CASE;HIGH POTENTIAL REQUIREMENTS-EACH UNIT CAN WITHSTAND 500 VOLTS ACAT 60 HZ P.S. FOR 15 SECONDS
SUPPSupplementary FeaturesINDICATOR ENERGIZED POSITION BACKGROUND POSITION LUSTERLESS BLACK COLORNO. 37038;INDICATOR DE-ENERGIZED POSITION (OFF) CHARACTERS LUSTERLESS WHITE COLOR NO. 37875 ON RED BACKGROUND COLOR NO. 31158;WORD OFF IS 0.094 IN. HIGHNOMINAL;BACK SURFACE TO BE FREE OF PAINT


Back to Top
Back to Top