6695-01-097-0441

TESTER,OXYGEN MASK


6695-01-097-0441 (6695010970441, 010970441)
Part Numbers (5 listings): TAMQ-1A | MIL-T-25620 | MQ-1A | 6504 | 1854 |
Summary

FSG 66 / FSC 6695

DEMIL: Q

DEMIL INT: 6

HMIC: N

Date Created: 3 Jul 1980

Unit Weight: 11.0 lbs

Unit Size: 20in x 18in x 16in

Unit Pack Cube: 3.333 cu ft

MSDS: None

Hazmat: None

Export License Required:
Munitions List Item or Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6695-01-097-0441 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
TA MQ-1A3 - Design Control Reference2 - Production ItemTRANSAERO, INC.  27541      
MIL-T-256204 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
MQ-1A4 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
65045 - Replaced / Discontinued2 - Production ItemTEC AIR SERVICE INC  26869      
18545 - Replaced / Discontinued2 - Production ItemWINDING SPECIALISTS CO., INC.  30150      
MQ-1A5 - Replaced / Discontinued2 - Production ItemWINDING SPECIALISTS CO., INC.  30150      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 6695-01-097-0441 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
666695010970441A2390077777X41QNAA3 Jul 1980
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6695

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Combination and Miscellaneous Instruments

010970441

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6695-01-097-0441

A23900

Federal Item Identification Guide (FIIG_4065)

77777

Item Naming Code (INC_4080)

3 Jul 1980

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

1

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name does not exist.

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 6695-01-097-0441 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
YW011 Apr 1991
ZP011 Apr 1991
ZC011 Apr 1991
ZH011 Apr 1991
ZB011 Mar 1994
YJ011 Oct 1995
A739A7202H3DTB1 Sep 2000
FGG4FEE42HFDFR1 Sep 2000
NAGSNAES2H3DJAGG1 Sep 2000
YA011 Oct 2000
ZR011 Dec 2007
ZU011 May 2008
WP011 Jun 2011
ZX011 Jan 2014
ZM011 Feb 2015
Code Definitions

2

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition for the first. time. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

3

Nonconsumable Item Material Support Code (NIMSC_0076)


End Item Primary Inventory Control Activity. This code identifies SICA managed end items or equipment assigned to another service PICA that is responsible for the wholesale logistics support functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance, if required, to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store, and issue functions for SICA activities. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

TBDSOR

Depot Source of Repair Codes (DSOR_0903)


Tobyhanna Army Depot (TYAD), PA

FRDSOR

Depot Source of Repair Codes (DSOR_0903)


Warner-Robins Air Logistics Center (WR-ALC), Robins AFB, GA

JADSOR

Depot Source of Repair Codes (DSOR_0903)


Fleet Readiness Center South East (FRC-SE), Jacksonville FL

GG

Supplementary Receivers (SUPPLM_RCVR_2534)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG C - REFERENCE NUMBER | NSN 6695-01-097-0441 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZZTA MQ-1A  27541  
414SBMIL-T-25620  81349   CAGE/81349
414SBMQ-1A  81349   CAGE/81349
525SB1854  30150  
4524SBDMQ-1A  30150  
525SB6504  26869  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6695-01-097-0441 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59703 Jul 1980
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Jul 1980

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6695-01-097-0441 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SEU72EZ9AHZF058240X33170RECORDING-DEVICES-GAUGES-METERS-NOI1
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

U

Less Than Carload (LCL_CD_2760)


50

72E

Water Commodity Code (WRT_CMDTY_CD_9275)


Engineer and Material Handling Equipment, Test/Tool sets and Equipment

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

F

Less Than Truckload (CLAS_RTNG_CD_2770)


150

058240

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

33170

Uniform Freight Classification (UFC_CD_MODF_3040)

RECORDING-DEVICES-GAUGES-METERS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 6695-01-097-0441 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFLZVU1SEA0
DAB17CU1FEA0
DNNRPVU1WEA0
Code Definitions

FLZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

S

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

B17

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


US Army Aviation and Missile Command (Air), ATTN: AMSMI-LC-MM-C, Redstone Arsenal, AL 35898-5230

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

F

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

W

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


NAVY: Ground Support Equipment-End Items

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 6695-01-097-0441 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
ASADW100011.0 lbs20in x 18in x 16in3.333 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00FAGFHED00O03EQM
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP51100045.0 lbs30.5in x 20.5in x 20.5in7.417 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00EANAXED00B03O
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

S

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Secondary Inventory Control Activity (SICA)

A

Item Type Storage Code (ITM_TYP_STOR_5156)


Heated General Purpose – Heated 40 F and above

DW

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 52 as follows: Item shall be cleaned, wrapped, blocked and braced in an interior carton fabricated in accordance with ASTM-D5118, Class domestic. MIL-PRF-131 barrier material, sealed as required, shall be utilized around the first container. The cushioning, to be specified under the cushioning code and in the thickness required to adequately protect the item, shall be placed between the barrier and the outer container.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

51

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

11.0 lbs

Unit Pack Weight (UP_WT_5153)

20in x 18in x 16in

Unit Pack Size (UP_SZ_5154)

3.333 cu ft

Unit Pack Cube (UP_CU_5155)

45.0 lbs

Unit Pack Weight (UP_WT_5153)

30.5in x 20.5in x 20.5in

Unit Pack Size (UP_SZ_5154)

7.417 cu ft

Unit Pack Cube (UP_CU_5155)

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

FA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-P-130, laminated and creped wrapping paper

GF

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


MIL-PRF-26514, Type I, Class 2, Grade B, flexible polyurethane foam, medium load range

H

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


2 inches thick

ED

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

O

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container is not an acceptable shipping container.

03

Special Marking Code (SP_MKG_CD_5169)


Mehod 50

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

EA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-DTL-17667, neutral wrapping paper

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

ED

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

03

Special Marking Code (SP_MKG_CD_5169)


Mehod 50

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6695-01-097-0441 Submit RFQ
MRCDecoded RequirementClear Text Reply
TEXTGeneral Characteristics Item DescriptionTESTER CONSISTS OF CASE 1,OXYGEN EQUIPMENT WHICH INCLUDES FLOW INDICATOR 1,PRESSURE GAGE 1,OXYGEN REGULATOR 1,MASK HOSE 1,INLET FITTING T-FITTING 1;COMMUNICATIONS AND GOGGLE EQUIPMENT WHICH INCLUDES POWER UNIT 1,HEADSET-MICROPHONE-GOGGLE EQUIPMENT TEST CIRCUIT 1;CASE MADE OF FIBERGLASS,ALUMINUM OR FIBERBOARD MATERIAL;FINISH DURABLE BLACK PER NO 33538 OF FED-STD-595;PANEL IN CASE RECESSED;CASE DIMENSIONS 12.0 IN. DEPTH BY 17.0 IN. LONG BY 10.0 IN. HIGH,3.062 INCH OF HEIGHT ARE TOP OF CASE;POWER UNIT CAPABLE OF CONVERTING 115 VAC,60 HZ;OUTPUT 28VDC,200MA;6 FOOT HEAVY DUTY ELECTRICAL CORD
FEATSpecial FeaturesITEM IS A PORTABLE TESTER FOR PRE FLIGHT CHECK OF PRESSURE DEMAND OXYGEN MASKS,PERSONAL INTERCOM EQUIPMENT AND EEU-2P GOGGLES


Back to Top
Back to Top