Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
04106 | 3 - Design Control Reference | 9 - No Longer Used | BELL AND HOWELL PHILLIPSBURG CO | 06650 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
67 | 6730 | 002408636 | A32900 | 03037 | X | 4 | 9 | A | N | U | 0 | 1 Jan 1961 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 1 | 1 | CX | 0 | 4 Sep 1986 | 6730002399680 | 29 Aug 1986 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ATDC | Drive Motor Voltage Rating | 115.0 ALTERNATING CURRENT |
AZZB | Amplifier Location | INTEGRAL |
ANWN | Amplifier Output Rating In Watts | 12.0 |
BFMF | Cooling Method | FORCED AIR |
ACSY | Furnished Items And Quantity | 4 BRUSH, CARBON AND 1 BRUSH, CLEANING AND 1 CARRYING CASE AND 9 LAMP, INDICATING AND 4 LAMP, PROJECTION AND 1 LENS, CONDENSER AND 6 OIL, LUBRICATING AND 1 REEL, FILM |
CBBL | Features Provided | PORTABLE AND TILTABILITY |
CTPH | Frame Rate Per Second | 16 FIXED AND 24 FIXED |
FREQ | Frequency In Hertz | 50.0 AND 60.0 |
AZYS | Material Width | 16.0 MILLIMETERS |
CHQR | Maximum Overall Height | 14.000 INCHES |
CHQP | Maximum Overall Length | 16.500 INCHES |
CHQQ | Maximum Overall Width | 9.500 INCHES |
ARNH | Operating Position | FORWARD |
AEWX | Lamp Voltage Rating In Volts | 115.0 |
AEWS | Lamp Wattage Rating In Watts | 750.0 AND 1000.0 |
BKHF | Lens Focal Length | 2.00 INCHES NOMINAL |
AZYZ | Lens Aperture Size | 1.6 |
AZYY | Projection Lamp Type | INCANDESCENT |
AZYR | Projection Material And Type Accommodated | REEL SILENT AND REEL SOUND |
AZYX | Reel Capacity | 2000.0 FEET |
AZYW | Sound Track Type | OPTIC |
AZZC | Speaker Location | EXTERNAL |
BBXG | Speaker Wattage Rating In Watts | 12.0 |
BBXH | Speaker Quantity | 1 |
FAAZ | Phase | SINGLE |